The area in a camping unit that contains constructed features, such as picnic tables, grills, fire rings, utilities, and other related elements, and may be located adjacent to or near a...
Search Results "Utility Hook-up"
-
Camp Living Area
-
4.7 Utilities including Water Hydrants at Recreation Sites
-
4.7.1 General
Electric, water, sewage, and other types of utilities shall comply with section 4.7....
-
4.7.2 Controls and Operating Mechanisms
Water hydrants and water utility hookups shall not be required to comply with the operable parts requirements in ABAAS section 309.4 until models that comply are readily available from more...
-
4.7.3 Slope
The slope of the clear floor or ground spaces required by section 4.0 shall not exceed 1:48 (2 percent) in any direction. Exception. When the surface is not paved or is not...
-
4.7.4 Surface
The surface of the clear floor or ground spaces required by section 4.0 shall be firm and stable. The type of surface should be appropriate to the setting and level of development.
-
4.7.5 Openings
Openings in surface of the clear floor or ground spaces required by section 2.0 shall not allow passage of a sphere more than 1/2 inch (13 mm) in diameter. Where possible, elongated...
-
4.7.8 Utility and Dump Station Hookup Clear Floor or Ground Space
The clear floor or ground space around utility and dump station hookups shall be at least 30 inches (760 mm) by 60 inches (1525 mm)....
-
Outdoor Constructed Features
The proposed rule contained separate scoping and technical requirements for picnic tables, fire rings, grills, fireplaces, wood stoves, trash and recycling receptacles, water hydrants, utility...
-
1011.1 General
The section includes specific provisions for picnic tables (1011.4); fire rings, grills, fireplaces, and woodstoves (1011.5); water spouts at water hydrants and water utility hook-ups (1011.6...
-
1011.6 Water Spouts
This section requires water spouts at water hydrants and water utility hook-ups to be 28 inches minimum and 36 inches maximum above the ground....
-
6.13 Outdoor Constructed Features
Where provided on circulation paths or beach access routes at beaches, outdoor constructed features such as picnic tables, grills or water hydrants, shall comply with technical...
-
Current Accessibility Guidelines That Apply to the Forest Service
surfaces Pedestal grills Fireplaces Beach access Outdoor recreation access routes Camping units (eating and cooking areas, parking spurs, tent pads) Campground utility...
-
4.1.4(1) GENERAL EXCEPTIONS
Accessibility is not required to elevator pits, elevator penthouses, mechanical rooms, piping or equipment catwalks, lookout galleries, electrical and telephone closets, and general utility...
-
Utilities at Recreation Sites
In general, connect electricity hookups, drinking water faucets, outdoor rinsing showers, utility sinks, sewer hookups, and other utilities that are provided in recreation sites to the other...
-
Definition [F106.5]
Outdoor constructed features are picnic tables, fire rings, grills, fireplaces, wood stoves, trash and recycling receptacles, water hydrants, utility and sewage hookups, outdoor rinsing...
-
Clear Ground Space [1011.2]
Utility and sewage hookups 30 by 60 inches with the long side of the space adjoining or overlapping an accessible parking space or pull-up space for recreational vehicles....
-
Water Hydrants and Water Spouts [1011.2, 1011.3, and 1011.6]
There are different technical requirements for the clear ground space at water utility hookups in camping units required to provide mobility features, which are discussed in the next section...
-
Utility and Sewage Hookups [1011.2, 1011.3, and 1011.6]
At utility hookups, such as electrical service, water, cable or Internet connections, in camping units with mobility features and at sewage hookups in dump stations, a minimum of 30...
-
1011.2.1 Size and Location
Locate the space so that the water spout is 11 inches (280 mm) minimum and 12 inches (305 mm) maximum from the rear center of the long side of the space Utility...
-
1011.3 Operable Parts
Fire rings, grills, fireplaces, wood stoves, water hydrants, and water utility hookups shall comply with 309.4 to the extent practicable. 2....
-
1011.6 Water Spouts
Water spouts at water hydrants and water utility hook-ups shall be 28 inches (710 mm) minimum and 36 inches (915 mm) maximum above the ground....
-
Width of Spaces [1012.2]
Parking spaces and pull-up spaces for RVs must be at least 20 feet wide to accommodate RVs equipped with a lift (figure 27)....
-
1011.2.1 Size and Location
Locate the space so that the water spout is 11 inches (280 mm) minimum and 12 inches (305 mm) maximum from the rear center of the long side of the space Utility...