1011.2.1 Size and Location.

The size and location of the clear ground space shall be in accordance with Table 1011.2.1. Unless otherwise specified in Table 1011.2.1, one full unobstructed side of the clear ground space shall adjoin or overlap an outdoor recreation access route or a trail, as applicable, or another clear ground space.

Table 1011.2.1 Clear Ground Space
Outdoor Constructed Feature  
Minimum Size and Location
Picnic tables 36 inches (915 mm) on all usable sides of the table measured from the back edge of the benches

 

Fire rings, grills, fireplaces, and woodstoves

48 inches (1220 mm) by 48 inches (1220 mm) on all usable sides of the fire ring, grill, fireplace, and woodstove

Center the space on each usable side of the grill, fireplace, and woodstove

Trash and recycling receptacles 36 inches (915 mm) by 48 inches (1220 mm) positioned for forward approach to the receptacle opening; or 30 inches (760 mm) by 60 inches (1525 mm) positioned for a parallel approach to the receptacle opening

 

Water hydrants

72 inches (1830 mm) by 48 inches (1220 mm) with the long side of the space adjoining or overlapping an outdoor recreation access route or trail, as applicable, or another clear ground space

Locate the space so that the water spout is 11 inches (280 mm) minimum and 12 inches (305 mm) maximum from the rear center of the long side of the space

 

Utility and sewage hookups

30 inches (760 mm) by 60 inches (1525 mm) with the long side of the space adjoining or overlapping an accessible parking space or pull-up space for recreational vehicles

Locate the space so that the hook-ups are at the rear center of the space

Bollards or other barriers shall not obstruct the clear ground space in front of the hook-ups

 

Outdoor rinsing showers

60 inches (1525 mm) by 60 inches (1525 mm) centered on the shower heads

Locate the space so that the shower pedestal or wall with the shower head are at the rear end of the space

 

Benches

36 inches (915 mm) by 48 inches (1220 mm) positioned near the bench with one side of the space adjoining an outdoor recreation access route or trail, as applicable

The clear ground space shall not overlap the outdoor recreation access route or trail, or another clear ground space

 

Viewing Scopes

36 inches (915 mm) by 48 inches (1220 mm) positioned for forward approach to the viewing scope

Provide knee and toe clearance complying with 306 under the viewing scope

Locate the space so that the eyepiece is centered on the space

Advisory 1011.2.1 Size and Location. The usable sides of picnic tables, fire rings, grills, fireplaces, and woodstoves are the sides of the outdoor constructed feature that can be used for eating or serving food, building a fire, or cooking. All sides of picnic tables are generally usable, unless the picnic table is placed against a rock or tree that renders the side against the rock or tree not usable. All sides of fire rings and grills are generally usable, unless there is a wall or other structure on a side that renders the side not usable. The front sides of fireplaces and woodstoves are generally the usable side.