Section 604.8.1.5 covers the current ADA Standards for grab bars in wheelchair accessible compartments.
Search Results "Grab Bar"
Commonly Searched Documents
-
Grab Bars: ADA Standard Section 604.8.1.5
-
Position of Grab Bars: ADA Standard Section 609.4
Section 609.4 covers the current ADA Standards for the position of grab bars.
-
Grab Bars: ADA Standard Section 1009.4.5
At least one grab bar complying with 609 shall be provided on the transfer wall. Grab bars shall be perpendicular to the pool wall and shall extend the full depth of the transfer wall....
-
Grab Bars: ADA Standard Section 1009.5.7
At least one grab bar on each transfer step and the transfer platform or a continuous grab bar serving each transfer step and the transfer platform shall be provided....
-
Grab Bars: ADA Standard Section 604.5
Section 604.5 covers the current ADA Standards for grab bars that are used for water closets.
-
Grab Bars: ADA Standard Section 609
Section 609 covers the current ADA Standards for grab bars.
-
Grab Bars: ADA Standard Section 604.8.2.3
Section 604.8.2.3 covers the current ADA Standards for grab bars in ambulatory accessible compartments.
-
11B-604.8.1.5 Grab bars
Grab bars shall comply with Section 11B-609. A side-wall grab bar complying with Section 11B-604.5.1 shall be provided and shall be located on the wall closest to the water closet....
-
Spacing: ADA Standard Section 609.3
Section 609.3 covers the current ADA Standards for the grab bar spacing between the wall, objects above, below and at the ends of the grab bar.
-
Grab Bars: ADA Standard Section 604.9.4
Section 604.9.4 covers the current ADA Standards for grab bars for children's use water closets.
-
Fittings: ADA Standard Section 609.6
Section 609.6 covers the current ADA Standards for the grab bar fittings.
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
-
11B-1009.5.7 Grab bars
At least one grab bar on each transfer step and the transfer platform or a continuous grab bar serving each transfer step and the transfer platform shall be provided....
-
Grab Bars: ADA Standard Section 607.4
Section 607.4 covers the current ADA Standards for bathtub grab bars.
-
Grab Bars: ADA Standard Section 608.3
Section 608.3 covers the current ADA Standards for grab bars in shower compartments.
-
GRAB BAR
[DSA-AC] A bar for the purpose of being grasped by the hand for support. Advisory Definition of GRAB BAR....
-
11B-608.3 Grab bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....
-
11B-607.4 Grab bars
Where separate grab bars are required on adjacent walls at a common mounting height, an L-shaped or U-shaped grab bar meeting the dimensional requirements of Section 11B-607.4.1 or 11B-607.4.2...
-
General: ADA Standard Section 609.1
Section 609.1 of the ADA Standards covers information in the current ADA Standards for grab bars in toilet facilities and bathing facilities.
-
11B-604.5 Grab bars
Grab bars for water closets shall comply with Section 11B-609. Grab bars shall be provided on the side wall closest to the water closet and on the rear wall....
-
Cross Section: ADA Standard Section 609.2
Section 609.2 covers the current ADA Standards for grab bar cross sections.
-
11B-609 Grab bars
[See subsections ...]
-
Side Wall: ADA Standard Section 604.5.1
Section 604.5.1 covers the current ADA Standards for side wall grab bars that are used for water closets.