., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp with a maximum slope of 1:8 is permanently installed....
Search Results "Maximum Reach Depth"
-
1132A.4, Item 4
-
11B-407.4.10.1 Location
Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above the floor of the car....
-
11B-407.4.10.1 Location
Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above the floor of the car....
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above...
-
307.3 Post-Mounted Objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above...
-
R402.3 Post-Mounted Objects
Where objects are mounted on free-standing posts or pylons and the objects are 685 mm (2.25 ft) minimum and 2030 mm (6.7 ft) maximum above the finish surface, the objects shall overhang...
-
Accessible - Changes in Level
The maximum slope of a ramp in new construction shall be no greater than 1;12....
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above...
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above...
-
11B-604.2 Location
The centerline of the water closet shall be 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432...
-
Perpendicular Curb Ramps (R304.2) (Section-by-Section Analysis)
A maximum slope of 10 percent is specified for the flared sides of perpendicular curb ramps where a pedestrian circulation path crosses the curb ramp....
- Assisted Living Directory
-
Shelves and Maneuvering Space
It is not necessary to locate all merchandise within reach of people who use wheelchairs....
-
American Association of the Deaf-Blind
Mission Statement: To ensure that all deaf-blind persons achieve their maximum potential through increased independence, productivity, and integration into the community....
- Jacksonville Area Center for Independent Living (JACIL) - Jacksonville, Havana, IL
-
309.4 Operation
The force required to activate operable parts shall be 5 pounds (22.2 N) maximum....
-
608.5.1 Transfer Type Shower Compartments
transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum...
-
4.7.7 Water Spouts
Water spouts shall be located in the space so that the water spout is 11 inches (280 mm) minimum and 12 inches (305 mm) maximum from the rear center of the long side of the clear floor or...
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
11B-608.5.1 Transfer type shower compartments
transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum...
- SLOPE Waste Receptacles
-
Knee & Toe Space [M303.2.4]
, female only data; technical information; consideration of positioning methods 28" minimum Unobstructed Floor Space Abdomen-to-caster wheel depth, combined male and...
- Bobrick Recessed Paper Towel Dispenser/Waste Receptacle B-39003