Rough Wall Opening: 15 7/8" W, 26 1/4" H, 4" min. depth (405 x 665 x 100mm)....
Search Results "Maximum Reach Depth"
- Bobrick ConturaSeries Recessed Waste Receptacle with LinerMate B-43644
- Bobrick TrimLineSeries Recessed Seat Cover Dispenser B-3013
-
607.4.2.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the bathtub...
-
Protrusions
Objects may protrude into the space a maximum of 6 inches along the front of the space, if they are between 9 inches and 27 inches maximum above the floor....
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be 1/2 inch (13 mm) high maximum in accordance with 303....
- Kawneer North America NX-8900 Terrace Doors
-
Tips for Communicating with Individuals with Mobility Impairments
If you telephone the individual, allow the phone to ring longer than usual to allow extra time for the person to reach the telephone....
-
6 [§ 4.7.7]
6 [§ 4.7.7] Detectable warnings are dome-shaped bumps that should cover the entire width and depth of the ramp run....
-
Is it OK to examine a patient who uses a wheelchair in the wheelchair, because the patient cannot get onto the exam table independently?
(See Part 4 of this publication for a more in-depth discussion of accessible exam tables.)...
-
Comparison of Single-User Toilet Room Layouts: Plan 3
An out-swinging door also minimizes the overall layout depth and cannot swing over the required clear floor space or clearance at any accessible plumbing fixture....
-
11B-705.1.2.2.2.1 One entrance/exit point
Where it is technically infeasible to provide a minimum 72 inches (1828 mm) wide turning space, as measured perpendicular to the curb, the depth of detectable warnings may be reduced to...
-
Height: ADA Standard Section 1005.2.1
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
11B-812.5.4 Arrangement
Vehicle spaces installed in existing facilities shall comply with Section 11B-812.5.4 to the maximum extent feasible....
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the horizontal...
-
Signal Type: ADA Standard Section 407.4.8.2.1
Section 407.4.8.2.1 covers the current ADA Standards for the signal type of audible elevator car indicators.
-
11B-809.10.8.1 Location
The top of the lavatory rim shall be 34 inches (864 mm) maximum above the finished floor....
-
11B-812.5.4 Arrangement
Vehicle spaces installed in existing facilities shall comply with Section 11B-812.5.4 to the maximum extent feasible....
-
11B-809.10.6.4 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm) minimum...
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the horizontal...
-
Clear Width: ADA Standard Section 403.5.1
Section 403.5.1 covers the current ADA Standards for the clear width of walking surfaces that are part of an accessible route.