Section 703.3 provides specifications for braille, including the dimensions and position. Comment. Braille is to be located below the corresponding text....
Search Results "Maximum Dimension"
-
Braille Specifications
-
505.6 Gripping Surface
distance between horizontal projections and the bottom of the gripping surface shall be permitted to be reduced by 1/8 inch (3.2 mm) for each ½ inch (13 mm) of additional handrail perimeter dimension...
-
5.2.1.2 Transfer Surface Depth Recommendation for M301
The Committee easily supported this increase as existing equipment already encompassed this dimension. The Committee reviewed anthropometric data from a variety of sources. Dr....
-
11B-505.6 Gripping surface
distance between horizontal projections and the bottom of the gripping surface shall be permitted to be reduced by 1/8 inch (3.2 mm) for each ½ inch (12.7 mm) of additional handrail perimeter dimension...
-
T210 Wheelchair Spaces
manufacturer suggested, in response to the 2010 NPRM, that the Access Board add language in the final rule that would allow additional spaces, even if they do not meet the minimum required dimensions...
-
Sight Lines
However, sports arenas and other facilities where spectators may stand during events add a critical dimension to achieving lines of sight from wheelchair spaces....
-
REDUCTION AND ANALYSIS OF DATA
The analyses reveal important information about the physical dimensions, speeds, etc. for various user types and, thus, how well those various users might be accommodated on facilities designed...
-
505.6 Gripping Surface
distance between horizontal projections and the bottom of the gripping surface shall be permitted to be reduced by 1/8 inch (3.2 mm) for each ½ inch (13 mm) of additional handrail perimeter dimension...
-
11B-608.3.2 Standard roll-in type shower compartments
Grab bars shall be installed 6 inches (152 mm) maximum from adjacent walls. [2010 ADAS] 608.3.2 Standard Roll-In Type Shower Compartments. ...
-
M303.2.4.2.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum measured from the toe end of the wheelchair...
-
M305.3.2 Height (Section-by-Section Analysis)
For horizontal supports, the MDE NPRM proposed a gripping surface height of 34 inches minimum and 38 inches maximum above the standing surface....
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
Submerged Depth
Submerged Depth Sloped entries must extend to a depth between 24 inches minimum and 30 inches maximum below the stationary water level....
-
407.2.2.3 Audible Signals
Audible signals shall have a frequency of 1500 Hz maximum. Verbal annunciators shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
Running Slope [1016.7.1]
Table 3—Maximum Running Slope and Segment Length Running Slope of Segment of Outdoor Recreation Access Route Maximum Length of Segment Steeper Than But Not...
-
11B-411.2.1.2.3 Accessibility function button
Each dot shall have a base diameter of 0.059 inch (1.5 mm) minimum and 0.063 inch (1.6 mm) maximum and a height of 0.025 inch (0.6 mm) minimum and 0.037 inch (0.9 mm) maximum....
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
Rise
The maximum length of a run is determined by the rise (30 inches maximum) and the slope: Max. Rise Slope Max. Length Max. Rise Slope Max....
-
11B-608.3.2 Standard roll-in type shower compartments
Grab bars shall be installed 6 inches (152 mm) maximum from adjacent walls. [2010 ADAS] 608.3.2 Standard Roll-In Type Shower Compartments....
-
11B-225.2.3 Library book stacks
Book stacks available for public use shall be 54 inches (1372 mm) maximum above the finish floor....
-
407.2.2.3 Audible Signals
Audible signals shall have a frequency of 1500 Hz maximum. Verbal annunciators shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
407.2.2.3 Audible Signals
Audible signals shall have a frequency of 1500 Hz maximum. Verbal annunciators shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
1009.5.7 Grab Bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above each step and transfer platform....