Fan shall be a large, single inlet centrifugal type for maximum capacity, and shall deliver 150 C.F.M....
Search Results "Maximum Dimension"
- Excel Dryer, Inc. CAST Cover Series HANDS ON® Push Button Activated Hand Dryers and Hair Dryers
-
General: ADA Standard Section 702.1
have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1), except that the maximum...
-
Ground Level: ADA Standard Section 1008.2.4.1
The clear width of accessible routes shall be permitted to be 36 inches (915 mm) minimum for a distance of 60 inches (1525 mm) maximum provided that multiple reduced width segments are separated...
-
Handrails: ADA Standard Section 1009.3.3
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
-
11B-411.2.2.2 Verbal identification
The verbal annunciator shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
11B-1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (838 mm) minimum and 38 inches (965 mm) maximum....
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
-
11B-1008.2.4.1 Ground level
The clear width of accessible routes shall be permitted to be 36 inches (914 mm) minimum for a distance of 60 inches (1524 mm) maximum provided that multiple reduced width segments are separated...
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
-
11B-1008.2.4.1 Ground level
The clear width of accessible routes shall be permitted to be 36 inches (914 mm) minimum for a distance of 60 inches (1524 mm) maximum provided that multiple reduced width segments are separated...
-
11B-1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (838 mm) minimum and 38 inches (965 mm) maximum....
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
11B-411.2.2.2 Verbal identification
The verbal annunciator shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
11B-604.3.2 Overlap
Notice CAN 2-11B, dated 9/9/14, which includes the following interpretation of Subsection 11B-604.3.2: Showers are fixtures including a 30 inch x 60 inch clear receptor with a minimum/maximum...
-
11B-604.3.2 Overlap
Notice CAN 2-11B, dated 9/9/14, which includes the following interpretation of Subsection 11B-604.3.2: Showers are fixtures including a 30 inch x 60 inch clear receptor with a minimum/maximum...
-
505.7.1 Circular Cross Section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
706.4 Sound Pressure Level
Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....
-
R302.5.2 Not Within Street or Highway Right-of-Way
Where pedestrian access routes are not contained within a street or highway right-of-way, the grade of pedestrian access routes shall be 5 percent maximum....
-
810.10 Track Crossings
EXCEPTION: Openings for wheel flanges shall be permitted to be 2 1/2 inches (64 mm) maximum....
-
T304.4 Operation
The force required to activate operable parts shall be 5 lbf (22.2 N) maximum....
-
11B-309 Operable parts
SECTION TITLE NOTES 11B-309 Operable parts Adds to existing exception for 5 lb. maximum operating...
-
604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1525 mm) minimum and a width of 35 inches (890 mm) minimum and 37 inches (940 mm) maximum....
-
1009.6.2 Handrails
The width between handrails shall be 20 inches (510 mm) minimum and 24 inches (610 mm) maximum. Handrail extensions required by 505.10.3 shall not be required on pool stairs....