Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....
Search Results "Maximum Dimension"
-
11B-706.4 Sound pressure level
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
Background
Background While the current ADA/ABA Accessibility Guidelines (ADA/ABA Guidelines) make reference to standard industry construction tolerances as they relate to the dimensions given in...
- Landscape Forms Inc. Petoskey Bench Collection
-
Can parking signage height be considered a "safe harbor"?
No specific height dimension given. For an older property with parking signs mounted at, say 45" inches to the bottom, are these protected by the safe harbor rule? ...
- Doka Oval Interior Wall Sconce by Hampstead
- Brady Worldwide Reserved Parking Sign 103747
-
11B-604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1524 mm) minimum and a width of 35 inches (889 mm) minimum and 37 inches (940 mm) maximum....
-
703.2.8 Line Spacing
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....
-
604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1525 mm) minimum and a width of 35 inches (890 mm) minimum and 37 inches (940 mm) maximum....
-
M305.3.2.2 Vertical Position
The height of the lowest end of the gripping surface on vertical standing supports shall be 34 inches (865 mm) minimum and 37 inches (940 mm) maximum above the standing surface....
-
903.3 Size
Benches shall have seats that are 42 inches (1065 mm) long minimum and 20 inches (510 mm) deep minimum and 24 inches (610 mm) deep maximum....
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck. Figure 1009.4.2 Transfer Wall Height...
-
1009.6.2 Handrails
The width between handrails shall be 20 inches (510 mm) minimum and 24 inches (610 mm) maximum. Handrail extensions required by 505.10.3 shall not be required on pool stairs....
-
703.2.8 Line Spacing
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....
-
604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1525 mm) minimum and a width of 35 inches (890 mm) minimum and 37 inches (940 mm) maximum....
-
R302.5.3 Within Pedestrian Street Crossings
Where pedestrian access routes are contained within a pedestrian street crossing, the grade of pedestrian access routes shall be 5 percent maximum....
-
1009.6.2 Handrails
The width between handrails shall be 20 inches (510 mm) minimum and 24 inches (610 mm) maximum. Handrail extensions required by 505.10.3 shall not be required on pool stairs....
-
903.3 Size
Benches shall have seats that are 42 inches (1065 mm) long minimum and 20 inches (510 mm) deep minimum and 24 inches (610 mm) deep maximum....
-
602.5 Spout Location
The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers....
-
505.7.1 Circular Cross Section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
R409.7.1 Circular Cross Section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 32 mm (1.25 in) minimum and 51 mm (2 in) maximum....
-
11B-903.3 Size
Benches shall have seats that are 48 inches (1219 mm) long minimum and 20 inches (508 mm) deep minimum and 24 inches (610 mm) deep maximum....
-
902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....