Requirements for accessible routes and ramps are applied to gangways, but exceptions to criteria for maximum rise and slope, handrail extensions, and level landings are provided....
Search Results "Maximum Dimension"
-
1003 Recreational Boating Facilities
-
M303.3.3.1 Running Slope
EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches (64 mm)....
-
1009.2.4 Seat Height
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...
-
810.10 Track Crossings
EXCEPTION: Openings for wheel flanges shall be permitted to be 2½ inches (64 mm) maximum. Figure 810.10 (Exception) Track Crossings...
-
T603.4 Movement
Wheelchair securement systems shall limit the movement of an occupied wheelchair to 2 inches (51 mm) maximum in any direction when secured in accordance with the manufacturer’s instructions...
-
4.6.3 Eyepiece
eyepiece for the telescope or periscope that is usable from a seated position for viewing each point of interest shall be positioned 43 inches (1090 mm) minimum and 51 inches (1295 mm) maximum...
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
M303.2.3 Wheelchair Spaces / Depth of Wheelchair Spaces for front or Rear Entry
Based on recent anthropometric data, NPRM proposes to increase minimum depth dimension from 48 to 58 inches – majority of members have no opinion or anticipation of a situation where requirement...
-
c. Transfer Surface Size for Diagnostic Equipment Used by Patients in the Supine, Prone, or Side-lying Position
These dimensions were based on the dimensions specified in the 2004 ADA and ABA Accessibility Guidelines for rectangular seats in roll-in showers (36 CFR Part 1191, App....
-
Clear Width of Circulation Paths and Maneuvering Clearances at Wheelchair Spaces
In the 2010 NPRM, the Access Board proposed specific minimum dimensions for the clear width of circulation paths within non-rail vehicles, as well as maneuvering clearances at wheelchair...
-
1009.6.1 Pool Stairs
EXCEPTION: Pool step riser heights shall not be required to be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum provided that riser heights are uniform....
-
§ 1194.25(j)(1)
(1) The position of any operable control shall be determined with respect to a vertical plane, which is 48 inches in length, centered on the operable control, and at the maximum protrusion...
-
1009.4.3 Wall Depth and Length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum....
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum. ...
-
1009.6.1 Pool Stairs
EXCEPTION: Pool step riser heights shall not be required to be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum provided that riser heights are uniform....
-
Height [4.18.2]
Recommendation: Specifying a urinal rim with the maximum projection available is recommended....
-
8.4 CARD CATALOGS
Maximum reach height shall comply with 4.2, with a height of 48 in (1370 mm) preferred, irrespective of reach allowed....
-
1132A.10 Door signal devices
The activating mechanism shall be mounted a maximum of 48 inches (1219 mm) above the floor and connected to permanent wiring....
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B-1009.4.3 Wall depth and length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....