Corresponding revisions have been made to similar requirements for shower compartments (608.6)....
Search Results "Compartment Width"
Commonly Searched Documents
-
Shower Spray Unit
-
c. Transfer Surface Size for Diagnostic Equipment Used by Patients in the Supine, Prone, or Side-lying Position
Commenter recommendations for transfer surface width ranged from 24 inches to 36 inches, while no commenters addressed the proposed depth of 15 inches....
-
11B-404.2.4 Maneuvering clearances
Maneuvering clearances shall extend the full width of the doorway and the required latch side or hinge side clearance. [Safe Harbor only applies to existing primary entrances.]...
-
Accessible Routes
The accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space,head room, surface, slope (maximum of 1:12 or 8.33%), changes in level...
-
Accessible Routes Adjacent to the Playing Surface
The accessible route provisions in ADAAG address slope (maximum of 1:12 or 8.33%), width (minimum of 36 inches), cross slope (maximum of 1:50 or 2%), handrails, and changes in level....
-
Openings [1018.6]
Where possible, elongated openings should be placed perpendicular, or as close to perpendicular as possible, to the dominant direction of travel or outside of the clear width of the beach...
-
R309.2.1 Wide Sidewalks
Where the width of the adjacent sidewalk or available right-of-way exceeds 4.3 m (14.0 ft), an access aisle 1.5 m (5.0 ft) wide minimum shall be provided at street level the full length...
-
D6. Vestibule Clear Floor Space
Minimum alcove depth of 48 inches if both doors open out Minimum alcove depth of 48 inches + door width when door swings into alcove...
-
4.26.2* Size and Spacing of Grab Bars and Handrails
The diameter or width of the gripping surfaces of a handrail or grab bar shall be 1‒1/4 in to 1‒1/2 in (32 mm to 38 mm), or the shape shall provide an equivalent gripping surface....
-
Escalators
Escalators must have a clear width of at least 32” and meet specific provisions in the ASME A17.1 Safety Code for Elevators and Escalators....
-
Required Compliance with the IBC [§207]
International Code Council (ICC), the IBC addresses the number of means of egress required and technical criteria for them, including fire–resistance rating, smoke protection, travel distance, width...
-
Transfer Surface (M301.2 and M302.2)
The technical criteria do not address the overall width and depth of patient support surfaces because of the diverse shape and size of these surfaces....
-
Three Additional Features for Van-Accessible Parking Spaces
notes) Sign with "van accessible" and the international symbol of accessibility mounted high enough so the sign can be seen when a vehicle is parked in the space 96" min. width...
-
11B-809.10.7.1 Floor space
Exception: The 48-inch (1219 mm) minimum clear width may be reduced to 36 inches (914 mm) minimum for lavatories, cabinets, wing walls, or privacy walls located immediately adjacent to a...
-
M301.4.1 Clearance in Base (Section-by-Section Analysis)
Where the width of the equipment is less than 36 inches wide, the proposed rule required the clearance to extend the full width of the equipment. Id....
- Rubbermaid 7818-88 Horizontal Baby Changing Station
- Inpro Corporation JointMaster® 316 Series Single Sightline for Carpet Floor Expansion Joint Covers
-
Door and Gate Surfaces: ADA Standard Section 404.2.10
Section 404.2.10 covers the current ADA Standards for door and gate surfaces on manual doors and gates.
-
Shared Use Paths: ADA Standard Section 2.
rights-of-way guidelines, which address access to sidewalks, streets, and other pedestrian facilities, provide requirements for pedestrian access routes, including specifications for route width...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
4.1 Wheeled Mobility Device Dimensions
Unoccupied Device Width Figure 3. Unoccupied Device Length The research data shows that the sizes of devices vary considerably from the values in the standards....
-
405 Ramps
Exceptions included in the final rule for the clear width (405.5) and handrails (405.8) of ramps located in employee work areas recognize constraints posed by various types of equipment....
-
Protruding Objects and Outdoor Recreation Access Routes
Protruding objects are defined as constructed features (such as signs) that extend into the clear width area of an outdoor recreation access route, resting interval, or passing space and...
-
1016.4 Passing Spaces
This section requires passing spaces to be provided at intervals of 200 feet maximum where the clear width of outdoor recreation access routes is less than 60 inches....