Section 404.2.6 covers the current ADA Standards for doors in series and gates in series.
Search Results "Shall"
Commonly Searched Documents
-
Doors in Series and Gates in Series: ADA Standard Section 404.2.6
-
Rest Stops, Emergency Roadside Stops, and Service Plazas: ADA Standard Section 217.4.5
Section 217.4.5 covers scoping requirements in the current ADA Standards for TTYs at rest stops, emergency roadside stops, and service plazas.
-
Forward Approach: ADA Standard Section 704.2.1.2
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
Maneuvering Clearance: ADA Standard Section 305.7
Section 305.7 covers the current ADA Standards for additional maneuvering clearance needed when the clear floor or ground space is located in an alcove.
-
General: ADA Standard Section 243.1
Section 243.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for shooting facilities and firing positions.
-
Height: ADA Standard Section 407.3.3.1
Section 407.3.3.1 covers the current ADA Standards for the height requirements of an elevators reopening device.
-
Drinking Fountains for Standing Persons: ADA Standard Section 602.7
Section 602.7 covers the current ADA Standards for drinking fountains for standing persons.
-
General: ADA Standard Section 708.1
Two-way communication systems shall comply with 708. Advisory 708.1 General. Devices that do not require handsets are easier to use by people who have a limited reach....
-
Height: ADA Standard Section 1008.3.1.2
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
Entrances for Inmates or Detainees: ADA Standard Section 206.4.9
Section 206.4.9 covers scoping requirements in the most current ADA Standards for accessible routes to Eentrances for inmates or detainees
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
11B-231.4.2 Partitions
Where solid partitions or security glazing separate visitors from detainees at least one of each type of cubicle or counter partition shall comply with Section 11B-904.6....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-706.4 Sound pressure level
Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
11B-405.4 Floor or ground surfaces
Floor or ground surfaces of ramp runs shall comply with Section 11B-302. Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
11B-217.4.5 Rest stops, emergency roadside stops, and service plazas
Where at least one public pay telephone is provided at a public rest stop, emergency roadside stop, or service plaza, at least one public TTY shall be provided....
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
11B-411.2.1.4.1.1 Arrangement
Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical...
-
11B-106.3 Undefined terms
The meaning of terms not specifically listed in Section 11B-106.5, and not defined in Chapter 2, Section 202, or in referenced standards shall be as defined by collegiate dictionaries in...
-
11B-208.3.3 Private garages accessory to residential dwelling units
Private garages accessory to residential dwelling units shall comply with Section 11B-208.3....
-
11B-213.1.1 Toilet facilities for designated user groups
Where separate toilet facilities are provided for the exclusive use of separate user groups, the toilet facilities serving each user group shall comply with Section 11B-213....
-
11B-206.4.4 Transportation facilities
In addition to the requirements of Sections 11B-206.4.2, 11B-206.4.3, and 11B-206.4.5 through 11B-206.4.9, transportation facilities shall provide entrances in accordance with Section 11B...
-
11B-216.5.2.1 Signs intended for use by pedestrians
Signs intended for use by pedestrians within parking facilities, including directional or informational signs indicating parking sections or levels, shall comply with the requirements of...