A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons....
Search Results "Shall"
Commonly Searched Documents
-
11B-407.4.7.1.5 Button spacing
-
412.2.6 Accessibility
[DSA-AC] In air traffic control towers, an accessible route shall not be required to serve the cab and the equipment areas on the floor immediately below the cab....
-
11B-247.1.2.7 Track crossings
Where it is necessary to cross tracks to reach transit boarding platforms, detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.7 shall be provided....
-
11B-203.4 Limited access spaces
Spaces not customarily occupied and accessed only by ladders, catwalks, crawl spaces, or very narrow passageways shall not be required to comply with these requirements or to be on an accessible...
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions....
-
11B-201.2 Application based on building or facility use
Where a site, building, facility, room, or space contains more than one use, each portion shall comply with the applicable requirements for that use....
-
11B-407.1.1 Combined passenger and freight elevators
When the only elevators provided for use by the public and employees are combination passenger and freight elevators, they shall comply with Section 11B-407 and with ASME A17.1....
-
11B-802.2.1 Lines of sight over seated spectators
Where spectators are expected to remain seated during events, spectators in wheelchair spaces shall be afforded lines of sight complying with Section 11B-802.2.1....
-
11B-804.6.5.1 Side-hinged door ovens
Side-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to the latch side of the oven door....
-
11B-705.1.2.6 Reflecting pools
When detectable warnings are provided at reflecting pools, it shall be 24 inches (610 mm) minimum and 36 inches (914 mm) maximum in width....
-
11B-249.1.2
Newly constructed commercial places of public amusement shall provide no fewer than one adult changing facility in compliance with Section 11B-813....
-
11B-602.8 Depth
Wall- and post-mounted cantilevered drinking fountains shall be 18 inches (457 mm) minimum and 19 inches (483 mm) maximum in depth....
-
RECOMMEND
[DSA-AC] Does not require mandatory acceptance, but identifies a suggested action that shall be considered for the purpose of providing a greater degree of accessibility to persons with...
-
Circular Cross Section: ADA Standard Section 609.2.1
Section 609.2.1 covers the current ADA Standards for circular grab bar cross sections.
-
Weather Shelters: ADA Standard Section 1006.4
A clear floor or ground space 60 inches (1525 mm) minimum by 96 inches (2440 mm) minimum shall be provided within weather shelters....
-
Height: ADA Standard Section 903.5
The top of the bench seat surface shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the finish floor or ground....
-
Transfer Entry: ADA Standard Section 1002.5.3
Where openings are provided for transfer to amusement ride seats, the openings shall provide clearance for transfer from a wheelchair or mobility aid to the amusement ride seat....
-
Floor or Ground Surfaces: ADA Standard Section 405.4
Section 405.4 covers the current ADA Standards for the floor or ground surfaces of ramps.
-
Line Spacing: ADA Standard Section 703.2.8
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....
-
General: ADA Standard Section 227.1
Section 227.1: General Scoping Requirements for sales and service.
-
Partitions: ADA Standard Section 231.4.2
Section 231.4.2 covers scoping requirements in the current ADA Standards for partitions.
-
Maximum Depth: ADA Standard Section 306.3.2
Section 306.3.2 covers the current ADA Standards for the maximum depth for knee clearance.
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
11B-903.5 Height
The top of the bench seat surface shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the finish floor or ground....