The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
Search Results "Shall"
Commonly Searched Documents
-
11B-404.2.6 Doors in series and gates in series
-
4.9.4 HANDRAILS
Stairways shall have handrails at both sides of all stairs....
-
4.34.5.5(2) Seat
The seat shall be 17 in to 19 in (430 mm to 485 mm) high measured from the bathroom floor and shall extend the full depth of the stall....
-
11B-407.2.3.1 Floor designation
Floor designations shall be provided in both raised characters and braille. Raised characters shall be 2 inches (51 mm) high....
-
11B-407.2.3.1 Floor designation
Floor designations shall be provided in both raised characters and Braille. Raised characters shall be 2 inches (51 mm) high....
-
General: ADA Standard Section 220.1
Section 220.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for automatic teller and fare machines.
-
Guest Room Doors and Doorways: ADA Standard Section 224.1.2
Section 224.1.2 covers scoping requirements in the current ADA Standards for transient lodging guest room doors and doorways.
-
11B-246.1 General
Outdoor developed areas shall comply with Section 11B-246....
-
11B-304.2 Floor or ground surfaces
Floor or ground surfaces of a turning space shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
11B-904.6 Security glazing
Where counters or teller windows have security glazing to separate personnel from the public, a method to facilitate voice communication shall be provided....
-
11B-610.3 Shower compartment seats
A seat in a standard roll-in shower compartment shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back wall to a point within...
-
11B-610.3 Shower compartment seats
A seat in a standard roll-in shower compartment shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back wall to a point within...
-
4.8.5* HANDRAILS
Handrails shall comply with 4.26 and shall have the following features: (1) Handrails shall be provided along both sides of ramp segments....
-
Use Zones: ADA Standard Section 1008.2.6.2
Ground surfaces located within use zones shall comply with ASTM F 1292 (1999 edition or 2004 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1)....
-
Residential Dwelling Units with Communication Features: ADA Standard Section 233.3.1.2
Section 233.3.1.2 covers scoping requirements in the current ADA Standards for residential dwelling units with communication features.
-
Spout Location: ADA Standard Section 602.5
Section 602.5 covers the current ADA Standards for the spout location of drinking fountains.
-
Size: ADA Standard Section 903.3
Benches shall have seats that are 42 inches (1065 mm) long minimum and 20 inches (510 mm) deep minimum and 24 inches (610 mm) deep maximum....
-
Long-Term Care Facilities: ADA Standard Section 223.3
Section 223.3 covers scoping requirements in the current ADA Standards for long-term care facilities.
-
Minimum Number: ADA Standard Section 234.4.2
Section 234.4.2 covers the most current ADA scoping requirements for the minimum number of wheelchairs spaces, transfer seats or devices at existing amusement rides.
-
Size: ADA Standard Section 604.8.2.1
Section 604.8.2.1 covers the current ADA Standards for the size of ambulatory accessible compartments.
-
Building Fire Alarm System: ADA Standard Section 809.5.1
Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke...
-
11B-227.1 General
Where provided, check-out aisles, sales counters, service counters, food service lines, queues, and waiting lines shall comply with Sections 11B-227 and 11B-904....
-
11B-246.5 Picnic areas
Where picnic tables are provided, at least one picnic table, and one additional table for each 20 tables or fraction thereof, shall be accessible and comply with Section 11B-902....
-
11B-604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1524 mm) minimum and a width of 35 inches (889 mm) minimum and 37 inches (940 mm) maximum....