subject to other similar requirements of law or code that require the lowest floor or the lowest structural member of the lowest floor be designed to a specified level at or above the base...
Search Results "Clearance in Base"
Commonly Searched Documents
-
11B-233.3.1.2.6.4 Test number three, unusual characteristics test
-
M305.3.1 Length
The length of gripping surfaces for standing supports shall be based on the position of the standing supports in relation to the standing surfaces they serve....
-
218 Transportation Facilities
These provisions are based on requirements located in Chapter 10 in the proposed rule....
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
703.2.5 Character Height
Character height measured vertically from the baseline of the character shall be 5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”....
-
M301.2.2, M302.2.2 Transfer Size
This transfer surface is located on the longitudinal (long) side of the stretcher—either right or left side Rationale: Based upon full committee discussion and harmonization with Exam...
-
402.4 Characters on Display Screens
Where ICT does not provide a screen enlargement feature, characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter “I”....
-
407.12.1.1 Vertical Plane for Side Reach (Section-by-Section Analysis)
The 48-inch dimension is based on the length of a stationary occupied wheelchair. This side reach requirement mirrors existing 508 Standards § 1194.25(j)(1) and Figure 1....
-
402.4 Characters
Where ICT does not provide a screen enlargement feature, characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter “I”....
-
2.6.1.2
The intersection of two outdoor recreation access routes providing a T-shaped space complying with ABAAS section 304.3.2 where the base and the arms of the T-shaped space extend 48 inches...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
§ 37.135(d) Phase-in of implementation
Each plan shall provide full compliance by no later than January 26, 1997, unless the entity has received a waiver based on undue financial burden....
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
- Spectrum Aquatics Gallatin Water Powered Assisted Access Lift
-
Pass Through Kitchen
Clearances for pass through kitchens address counters, appliances, or cabinets on two opposing sides....
-
Storage [9.2.2(4)]
However, since people who use wheelchairs may not be able to reach much beyond the toes, a forward reach is generally limited to those storage elements providing knee and toe clearances....
-
Shelf and Outlet
The shelf must provide a vertical clearance of at least 6 inches so that different types of portable TTY devices can be connected....
-
Horizontal Alignment
Horizontal Alignment The minimum clearance to an obstruction that should be provided along a horizontal curve is a function of the stopping sight distance and radius of the curve....
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Forward Approach Scooter
reaching over an obstruction in relation to the forward-most point, and the negative range implying that the reach target is brought closer to the person (such as on a table with knee clearance...
-
Feature 6 - Restrooms
An accessible lavatory has floor space in front so that a wheelchair user can approach it, knee clearance so the person can pull under it, and a lowered top surface height so the person...
-
Common Problems with Toilet Rooms
Ø The sink counter is too high, or there is insufficient knee clearance. Ø The sink has exposed hot water and drain pipes, which can cause serious burns....
-
STEP 2 Determine what is needed
Table 240.2.1.2 establishes a minimum level of ground level play components required to be on an accessible route, based on the number of elevated play components provided....
-
Recommendations
Recommendations Based on the data in Table 1 and the observations above, we recommend: a minimum flat surface of 40 in. length for platforms accommodating wheeled mobility devices...