Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
Search Results "Vertical Clearance"
-
603.2.3 Door Swing
- Allegion Falcon 24 Series Touch Bar Exit Device
-
ENTRANCE
An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibule if provided, the entry door or gate, and the hardware...
-
Cross Slope
in elevation, when measuring the trail tread from edge to edge perpendicular to the direction of travel This may be expressed as the percentage of change in elevation or as a ratio of vertical...
-
Do stories not required to be on an accessible route have to comply with the Standards?
This ensures access for people with disabilities who can use stairs and facilitates compliance should vertical access be achieved through later renovations or additions....
-
Entrance
An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibule if provided, the entry door or gate, and the hardware...
-
608.2.1 Transfer Type Shower Compartments
Clearance of 36 inches (915 mm) wide minimum by 48 inches (1220 mm) long minimum measured from the control wall shall be provided....
-
ACCESS AISLE
[DSA-AC] An accessible pedestrian space adjacent to or between parking spaces that provides clearances in compliance with this code....
-
EXECUTIVE SUMMARY
Vertical Alignment-Crest Vertical Curves The minimum length for a crest vertical curve is a function of the stopping sight distance, the algebraic difference in the upgrade and downgrade...
-
B) Accessible Route
An accessible route must be at least 36 inches wide, have no abrupt vertical changes in level (such as a step), have a running slope no more than 1:12 in most cases, and meet other requirements...
-
2.7 Tread Obstacles
Where the surface is paved or is elevated above the natural ground, obstacles shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point. ...
-
§ 38.73(d)(4) Exception
Where it is not operationally or structurally practicable to meet the horizontal or vertical requirements of paragraphs (d) (1), (2) or (3) of this section, platform or vehicle devices complying...
-
11B.707.7.1.3 Horizontally mounted display screen
Where display screens are mounted tipped away from the viewer 60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices shall be...
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
§ 38.125(b)(4) Power or equipment failure
Platforms stowed in a vertical position, and deployed platforms when occupied, shall have provisions to prevent their deploying, falling, or folding any faster than 12 inches/second or their...
-
§ 38.95(b)(4) Power or equipment failure
Platforms stowed in a vertical position, and deployed platforms when occupied, shall have provisions to prevent their deploying, falling, or folding any faster than 12 inches/second or their...
-
§ 38.23(b)(4) Power or equipment failure
Platforms stowed in a vertical position, and deployed platforms when occupied, shall have provisions to prevent their deploying, falling, or folding any faster than 12 inches/second or their...
-
11B.707.7.1.2 Angle-mounted display screen
Where display screens are mounted tipped away from the viewer 30 degrees to less than 60 degrees from vertical, the center line of the display screen and other display devices shall be no...
- Detecto 6550 Portable Wheelchair Scale Set-up
-
FOREWORD
Vertical Alignment/Crest Vertical Curves-Recumbent bicyclists had a required length of a crest vertical curve of 46.7 m (153 ft), less than the AASHTO value....
-
902.2 Clear Floor or Ground Space
Knee and toe clearance complying with 306 shall be provided....
-
902.2 Clear Floor or Ground Space
Knee and toe clearance complying with 306 shall be provided....
-
11B-407.4.10.3 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting device...
-
Running Slope (Grade)
This may be expressed as a ratio of vertical distance to horizontal distance or as the percentage of change in elevation. ...