For lifts with a signed installation contract before May 1, 2008: CCR, Title 8, Section 3094 provides safety regulations for Vertical Platform (Wheelchair) Lifts....
Search Results "Vertical Clearance"
Commonly Searched Documents
-
11B-410.8 Restriction sign
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
(C) NYCT’s interpretation of the ADA and DOT’s implementing regulations is too narrow.
To address another argument presented by NYCT,1 the ADA Accessibility Guidelines (ADAAG) do not, as NYCT contends, limit the requirement that “a means of accessible vertical access” be provided...
-
4.2.5* Forward Reach
If the high forward reach is over an obstruction, reach and clearances shall be as shown in Fig. 5(b)....
-
4.34.5.3 LAVATORY, MIRRORS, AND MEDICINE CABINETS
(2) If a cabinet is provided under the lavatory in adaptable bathrooms, then it shall be removable to provide the clearances specified in 4.22.6....
-
Are doors or gates to employee work areas required to comply?
Entry doors or gates to employee work areas are required to meet applicable requirements, including those for maneuvering clearance, on the exterior, but not the interior....
-
IDEA Center
A shelf location closest to the highest vertical free reach was used to measure high reach; mid level was set at or near the shoulder and the shelf for the lower reach was set at the MCP5...
- Bobrick ClassicSeries Surface Mounted Seat-Cover Dispenser B-221
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
1.17 Unobstructed view
purposes of this Consent Order, shall mean and refer to a view to the screen that is not blocked or interfered with by any seats, railings, or other objects and is configured to have visual clearance...
-
7. Lavatory
Is the lavatory (wash basin) in each accessible guestroom bathroom no more than 34" high with at least 29" high clearance under the front edge to allow persons who use wheelchairs to pull...
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
D. Beds in accessible guest rooms and sleeping rooms
Many individuals with disabilities have urged the Department to regulate the height of beds, particularly in accessible hotel guest rooms, and to require that such beds have clearance under...
-
Shower and Sauna Doors in Transient Lodging Facilities
The exemption to the section 224.1.2 requirement for a 32-inch wide clearance at doors to shower and saunas applies only to those showers and saunas in guest rooms which are not required...
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
11B-703.6.1 Pictogram field
The 6-inch vertical dimension applies to the field, not the symbol. The symbol may be smaller than the field....
-
407.2.2.2 Visible Signals
The visible signal elements shall be 2½ inches (64 mm) minimum measured along the vertical centerline of the element....
-
Gaps
spaces are provided on amusement rides, the floors of rides must be coordinated with the floors of the load and unload areas so that when the ride is at the load and unload position, the vertical...
-
608.7 Thresholds
In transfer type shower compartments, thresholds 1/2 inch (13 mm) high maximum shall be beveled, rounded, or vertical....
-
407.2.2.2 Visible Signals
The visible signal elements shall be 2 1/2 inches (64 mm) minimum measured along the vertical centerline of the element....
-
Adjustable height protocol
The amount of vertical distance that the seat was raised/lowered each time depended on the subject’s perceived and observed transfer abilities....