[See subsections ...]
Search Results "Floor Slope"
-
11B-231 Judicial facilities.
-
Additional benefits of water closet clearance standards
The standards requiring sufficient space in single-user toilet rooms for a wheelchair user to effect a side or parallel transfer are among the most costly (in monetary terms) of the...
-
§ 38.159(b)(6) Platform surface
(6) Platform surface. The platform surface shall be free of any protrusions of 1/4 inch (6.5 mm) high and shall be slip resistant. The platform shall have a minimum clear width of 28...
-
§ 38.83(b)(6) Platform surface
(6) Platform surface. The lift platform surface shall be free of any protrusions over 1/4 inch high and shall be slip resistant. The lift platform shall have a minimum clear width of...
-
11B-231.1 General
Judicial facilities shall comply with Section 11B-231.
-
11B-231.1 General
Judicial facilities shall comply with Section 11B-231.
-
11B-231 Judicial facilities
[See subsections ...]
-
(1)(a)
(a) The minimum clear floor area should be 35 inches (890 mm) by 60 inches (1525 mm)....
-
11B-302.1 General
Floor and ground surfaces shall be stable, firm, and slip resistant and shall comply with 11B-302. Exceptions: 1. ...
-
11B-302.1 General
Floor and ground surfaces shall be stable, firm, and slip resistant and shall comply with 11B-302. Exceptions: 1. ...
-
11B-302.1 General
Floor and ground surfaces shall be stable, firm, and slip resistant and shall comply with 11B-302....
-
11B-407.2.3.2 Reserved
ETA Editor's Note Imposing additional requirements regarding characters and colors, the preceding CBC requirements pertaining to elevator hoistway signs are more stringent...
-
11B-407.2.3.2 Reserved
ETA Editor's Note Imposing additional requirements regarding characters and colors, the preceding CBC requirements pertaining to elevator hoistway signs are more stringent...
-
4.32.2 Seating
If seating spaces for people in wheelchairs are provided at fixed tables or counters, clear floor space complying with 4.2.4 shall be provided....
-
4.32.2 SEATING
If seating spaces for people in wheelchairs are provided at tables, counters, or work surfaces, clear floor space complying with 4.2.4 shall be provided....
-
Overview
Large pools must have two accessible means of entry, with at least one being a pool lift or sloped entry; smaller pools are only required to have one accessible means of entry, provided...
-
4.7.5 Openings
Openings in surface of the clear floor or ground spaces required by section 2.0 shall not allow passage of a sphere more than 1/2 inch (13 mm) in diameter....
-
Forward Approach
Faucets, controls, and dispensers should be within the usable clear floor space to be within easy reach....
-
11B-233.3.1.2.6.5 Additional requirements.
1. Grab bar reinforcement complying with Sections 11B-809.10.5.2, 11B-809.10.6.4, or 11B-809.10.7.3. 2. Interior door opening width complying with Section 11B-404.3.1. 3....
-
11B-233.3.1.2.6.5 Additional requirements.
In buildings without elevators and where site impracticality test numbers one, two or three reduce the required number of residential dwelling units with adaptable features, the...
- Inpro Corporation JointMaster® DR Series Seal Expansion Joint Systems
-
4.1.3 Wheelchair Seating Space
Clear floor or ground space that is at least 30 inches by 48 inches shall be provided at each seating space that is required to be accessible and positioned for a forward approach to the...