Appendix 2- Photos of Participants in the IDEA Center Research Examples of High Seats: Examples of Very Large and Small Clear Floor Area Widths: Examples of Very Long...
Search Results "Floor Slope"
Commonly Searched Documents
-
Appendix 2- Photos of Participants in the IDEA Center Research
- Figure 810.3 Bus Shelters – Drawing from the U.S. Access Board
-
Permitted Means of Pool Access
Permitted Means of Pool Access Pool Type Sloped Entry Lift Transfer Walls Transfer Systems Stairs Swimming (less than 300 linear...
-
FIGURE 11A-10A KITCHEN SPECIFICATIONS
(1) 30" minimum countertop space for sink installation with removable base cabinet and finish flooring beneath the sink; 30" x 48" minimum clear floor space to allow parallel or forward...
-
2.4 Patient Areas
Is there space in the waiting room for wheelchair users to sit? Is there space in the exam room for an individual using a wheelchair or other mobility aid to move and...
-
Seating [4.32.2] and Knee Clearance [4.32.3]
Seating [4.32.2] and Knee Clearance [4.32.3] Knee space at least 27 inches high is required for a depth of 19 inches. The over-the-surface reach is limited to 25 inches if at...
-
7(1)(a)
(a) A clear floor space at least 30 inches by 48 inches that allows a parallel approach by a person in a wheelchair is provided at the range or cooktop and sink, and either a parallel or...
-
1133A.1 General
) (1) 30" minimum countertop space for sink installation with removable base cabinet and finish flooring beneath the sink; 30" x 48" minimum clear floor space to allow parallel...
-
11B-405.4 Floor or ground surfaces
Floor or ground surfaces of ramp runs shall comply with Section 11B-302. Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
11B-405.4 Floor or ground surfaces
Floor or ground surfaces of ramp runs shall comply with Section 11B-302. Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
11B-405.4 Floor or ground surfaces
Floor or ground surfaces of ramp runs shall comply with Section 11B-302. Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
1(2) Site impracticality
(2) Site impracticality. Covered multifamily dwellings with elevators shall be designed and constructed to provide at least one accessible entrance on an accessible route, regardless...
-
Conclusion
study found that the majority of participants (5th percentile) could transfer independently to the platform at a height that was within one inch of the mean wheelchair or scooter seat to floor...
- Accessible Parking Video Fact Sheet
-
7(2)(b)(v)
The top of the fixture rim is a maximum height of 2'10" above the finished floor. If kneespace is provided below the vanity, the bottom of the apron is at least 2'3" above the floor....
-
11B-233.3.1.2.6 Public housing facility site impracticality
The site impracticality tests in this section may be used to determine the number of required residential dwelling units with adaptable features in buildings without an elevator,...
-
11B-407.4.8.1.3 Floor arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. Exception: Reserved....
- Access Board: Toilet Rooms
-
1010.1.5 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....
-
Technical Memorandum TM 2013-14 Dining Surfaces
Length Clear floor space complying with TAS 305 for a forward approach is required for an accessible dining surface based on TAS 902.2....
-
4.6 Swimming Pools
There are at least 5 different ways to enter a pool that are accessible: you can use a lift, a sloped entry, a transfer wall, transfer steps, or accessible pool stairs. ...