A commenter pointed out that the provision for solid partitions or security glazing in visiting areas should be revised to be more consistent with the technical provision it references,...
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
-
Security Glazing
-
Slopes and Resting Intervals for Outdoor Recreation Access Routes
Runnign [sic] Slopes on ORARs Maximum Length of Segment Between Resting Intervals Steeper than But not Steeper than 1:20 (5 percent) 1:12 (8.33...
-
M301.4 Lift Compatibility
better patient transfer and positioning over a portable lift because the portable lift would need to access the diagnostic imaging table from its side or its far foot-end; and 2) table structural...
-
Parallel Approach: ADA Standard Section 704.2.1.1
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (255 mm) maximum....
-
Handrail Height: ADA Standard Section 1008.2.5.3.2
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
Height: ADA Standard Section 902.4.2
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the finish floor or ground....
-
Tray Slides: ADA Standard Section 904.5.2
The tops of tray slides shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
Incidental Spaces: ADA Standard Section 206.7.3
Section 206.7.3 covers scoping requirements in the most current ADA Standards for accessible routes to incidental spaces.
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground....
-
11B-1008.2.5.3.2 Handrail height
The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface....
-
11B-704.2.1.1 Parallel approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (254 mm) maximum....
-
11B-602.8 Depth
Wall- and post-mounted cantilevered drinking fountains shall be 18 inches (457 mm) minimum and 19 inches (483 mm) maximum in depth....
-
11B-705.1.2.6 Reflecting pools
When detectable warnings are provided at reflecting pools, it shall be 24 inches (610 mm) minimum and 36 inches (914 mm) maximum in width....
-
11B-206.7.3 Incidental spaces
Platform lifts shall be permitted to provide an accessible route to incidental spaces which are not public use spaces and which are occupied by five persons maximum....
-
11B-904.5.2 Tray slides
The tops of tray slides shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-904.5.2 Tray slides
The tops of tray slides shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-1008.2.5.3.2 Handrail height
The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface....
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground....
-
11B-602.8 Depth
Wall- and post-mounted cantilevered drinking fountains shall be 18 inches (457 mm) minimum and 19 inches (483 mm) maximum in depth....
-
11B-704.2.1.1 Parallel approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (254 mm) maximum....
-
11B-206.7.3 Incidental spaces
Platform lifts shall be permitted to provide an accessible route to incidental spaces which are not public use spaces and which are occupied by five persons maximum....
-
11B-705.1.2.6 Reflecting pools
When detectable warnings are provided at reflecting pools, it shall be 24 inches (610 mm) minimum and 36 inches (914 mm) maximum in width....
-
§382.55(b)(3)
(3) You must not require private security screenings of passengers with a disability to a greater extent, or for any different reason, than for other passengers....
-
11B-233.3.4.3 Alterations to residential dwelling units with adaptable features
Exception: Where any portion of a building’s exterior is preserved, but the interior of the building is removed, including all structural portions of floors and ceilings and a new building...