(2)
Search Results "Safe Harbor (FHA)"
Commonly Searched Documents
-
§ 36.304(d)(2)
-
17.1 Q. Is it correct that only the exterior side of the main entry door of covered multifamily dwellings must meet the ANSI requirements?
A. Yes. The exterior side of the main entry door is part of the public and common use areas and therefore must meet ANSI A117.1 1986 specifications for doors. These specifications...
-
7(2)(b)(vi)
(vi) Bathtubs and tub/showers located in the bathroom provide a clear access aisle adjacent to the lavatory that is at least 2'6" wide and extends for a length of 4'0" (measured from...
-
4.1 Q. If an owner adds four or more dwelling units to an existing building, are those units covered by the Fair Housing Act?
A. Yes, provided that the units constitute a new addition to the building and not substantial rehabilitation of existing units.
-
9.1 Q. If a building was used previously for a nonresidential purpose, such as a warehouse, office building, or school, and is being converted to a multifamily dwelling, must the building meet the requirements of the Fair Housing Act?
A. No, the Fair Housing Act applies to covered multifamily dwellings for first occupancy after March 13, 1991, and the Fair Housing Act regulation defines first occupancy as a...
-
Kitchen Work Surfaces
Comment. One commenter stated that "Element 12" in the chart accompanying the Guidelines for Requirement 2 (public and common use areas) seems to require a portion of the kitchen...
-
19.1 Q. If a sliding door track has a threshold of 3/4, does this trigger requirements for ramps?
A. No. The Guidelines at Requirement 4 provide that thresholds at doors, including sliding door tracks, may be no higher than 3/4 and must be beveled with a slope no greater than 1:2.
-
Section 2. Single-story dwelling unit
"Single-story dwelling unit" means a dwelling unit with all finished living space located on one floor.
-
5.2 Q. If a building design contains a mix of single-story flats on grade and single-story flats located above grade over a public parking area, do the flats over the parking area have to be accessible?
A. No. In the example in the above question, because some single-story flats are situated on grade, these flats would be the ground floor dwelling units and would be required to be...
-
5.1 Q...Would the first story of single-story dwelling units over the parking level be required to be accessible?
A. Yes. The Guidelines adopt and amplify the definition of ground floor found in HUD's regulation implementing the Fair Housing Act (see 24 CFR 100.201) to indicate that . . .where...
-
6.1 Q...do the dwelling units on both the first and second stories have to be made accessible?
A. Yes. By defining ground floor to be any floor of a building with an accessible entrance on an accessible route, the Fair Housing Act regulations recognize that certain buildings,...
-
7(1)(a)
(a) A clear floor space at least 30 inches by 48 inches that allows a parallel approach by a person in a wheelchair is provided at the range or cooktop and sink, and either a...
-
7(2)(a)
(a) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Cabinets under lavatories are acceptable provided the...
-
§100.205(c)
(c) All covered multifamily dwellings for first occupancy after March 13, 1991 with a building entrance on an accessible route shall be designed and constructed in such a manner that—
-
7(2)(b)(iv)
(iv) Toilets are located within bathrooms in a manner that permit a grab bar to be installed on one side of the fixture. In locations where toilets are adjacent to walls or bathtubs,...
-
7(2)(a)(ii)
(ii) Clear floor space is provided at fixtures as shown in Fig. 7 (a), (b), (c) and (d). Clear floor space at fixtures may overlap. Fig. 7 Clear Floor Space for...
-
(4) [sic] Thresholds at exterior doors
Subject to the exceptions for thresholds and changes in level at exterior areas constructed of impervious materials, the final Guidelines continue to specify that thresholds at...
-
3(2)
(2) Within individual dwelling units, doors intended for user passage through the unit which have a clear opening of at least 32 inches nominal width when the door is open 90...
-
4(4)
(4) Except as noted in paragraphs (5) and (6) below, thresholds at exterior doors, including sliding door tracks, are no higher than 3/4 inch. Thresholds and changes in level at...
-
7(2)(b)(v)
(v) Vanities and lavatories are installed with the centerline of the fixture a minimum of 1'3" horizontally from an adjoining wall or fixture. The top of the fixture rim is a maximum...
-
21.1 Q. Is a dwelling unit that has a split entry foyer...required to be accessible if it is a ground floor unit in a covered multifamily dwelling?
A. Yes. Under Requirement 4, there must be an accessible route into and through the dwelling unit. This would preclude a split level foyer, unless a properly sloped ramp can be...
-
Minimum Clear Corridor Width
A few commenters from the disability community advocated a minimum clear corridor width of 48 inches. However, the majority of commenters on this issue had no objection to the...
-
§100.205(c)(2)
(2) All the doors designed to allow passage into and within all premises are sufficiently wide to allow passage by handicapped persons in wheelchairs; and
-
§100.301(b)
(b) Nothing in this part limits the applicability of any reasonable local, State, or Federal restrictions regarding the maximum number of occupants permitted to occupy a dwelling.