5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests....
Search Results "Pull Side"
Commonly Searched Documents
-
5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests
-
Side reach (Section-by-Section Analysis)
Side reach. The 1991 Standards at section 4.2.6 establish a maximum side-reach height of 54 inches. The 2010 Standards at section 308.3.1 reduce that maximum height to 48 inches....
-
Side reach (Section-by-Section Analysis)
Side reach. The 1991 Standards at section 4.2.6 establish a maximum side-reach height of 54 inches. The 2010 Standards at section 308.3 reduce that maximum height to 48 inches....
-
11B-404.2.11 Vision lights
Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel...
-
9 [§ 4.7.5]
9 [§ 4.7.5] Curb ramps either have flared sides or vertical edges called returned curbs....
-
11B-404.2.11 Vision lights
Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel...
-
11B-404.2.11 Vision lights
Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel...
-
M301.2.3.2 Side Transfer Surface
Side transfer surfaces shall be 28 inches (710 mm) wide minimum and 28 inches (710 mm) long minimum....
-
5.3 Transfer Sides
5.3 Transfer Sides....
-
5.3.3.1 Transfer Sides Recommendation for Exam Chairs with Fixed Footrests
5.3.3.1 Transfer Sides Recommendation for Exam Chairs with Fixed Footrests Some examination chairs have footrests that get in the way of entry from the foot end, such as dental chairs...
- Safety Technology: the First 30 Years
-
[F] 907.4.2.2 Height
[F] 907.4.2.2 Height. The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor...
-
907.2.6 Group I
A manual fire alarm system and an automatic fire detection system shall be installed in Group I occupancies. An electrically supervised, automatic smoke detection system shall be...
-
907.2.7 Group M
A manual fire alarm system shall be installed in Group M occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit...
-
907.2.7.1 Occupant notification
During times that the building is occupied, in lieu of the automatic activation of alarm notification appliances, the manual fire alarm system shall be allowed to activate an alarm...
- Figure 404.2.4.1(k) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Push Side with Closer – Drawing from the U.S. Access Board
-
A2
Is the vehicle pull-up area relatively level (1:50 or 2% maximum slope in all directions)? Yes No...
-
5.3.3 Transfer Sides for Equipment Used by Patients in Seated Position
5.3.3 Transfer Sides for Equipment Used by Patients in Seated Position....
-
503.3 Access Aisle
Passenger loading zones shall provide access aisles complying with 503 adjacent to the vehicle pull-up space....
-
503.3 Access Aisle
Passenger loading zones shall provide access aisles complying with 503 adjacent to the vehicle pull-up space....
-
503.3 Access Aisle
Passenger loading zones shall provide access aisles complying with 503 adjacent to the vehicle pull-up space....
-
11B-503.3 Access aisle
Passenger drop-off and loading zones shall provide access aisles complying with Section 11B-503 adjacent and parallel to the vehicle pull-up space....
-
11B-503.3 Access aisle
Passenger drop-off and loading zones shall provide access aisles complying with Section 11B-503 adjacent and parallel to the vehicle pull-up space....
-
11B-503.3 Access aisle
Passenger drop-off and loading zones shall provide access aisles complying with Section 11B-503 adjacent and parallel to the vehicle pull-up space....