Side transfer surfaces shall be 28 inches (710 mm) wide minimum and 28 inches (710 mm) long minimum....
Search Results "Pull Side"
-
M301.2.3.2 Side Transfer Surface
-
5.3 Transfer Sides
5.3 Transfer Sides....
-
5.3.3.1 Transfer Sides Recommendation for Exam Chairs with Fixed Footrests
5.3.3.1 Transfer Sides Recommendation for Exam Chairs with Fixed Footrests Some examination chairs have footrests that get in the way of entry from the foot end, such as dental chairs...
- Safety Technology: the First 30 Years
-
[F] 907.4.2.2 Height
[F] 907.4.2.2 Height. The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor...
-
907.2.6 Group I
A manual fire alarm system and an automatic fire detection system shall be installed in Group I occupancies. An electrically supervised, automatic smoke detection system shall be...
-
907.2.7 Group M
A manual fire alarm system shall be installed in Group M occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit...
-
907.2.7.1 Occupant notification
During times that the building is occupied, in lieu of the automatic activation of alarm notification appliances, the manual fire alarm system shall be allowed to activate an alarm...
-
5.3.3 Transfer Sides for Equipment Used by Patients in Seated Position
5.3.3 Transfer Sides for Equipment Used by Patients in Seated Position....
-
A2
Is the vehicle pull-up area relatively level (1:50 or 2% maximum slope in all directions)? Yes No...
- Figure 404.2.4.1(k) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Push Side with Closer – Drawing from the U.S. Access Board
-
503.3 Access Aisle
Passenger loading zones shall provide access aisles complying with 503 adjacent to the vehicle pull-up space....
-
503.3 Access Aisle
Passenger loading zones shall provide access aisles complying with 503 adjacent to the vehicle pull-up space....
-
503.3 Access Aisle
Passenger loading zones shall provide access aisles complying with 503 adjacent to the vehicle pull-up space....
-
11B-503.3 Access aisle
Passenger drop-off and loading zones shall provide access aisles complying with Section 11B-503 adjacent and parallel to the vehicle pull-up space....
-
11B-503.3 Access aisle
Passenger drop-off and loading zones shall provide access aisles complying with Section 11B-503 adjacent and parallel to the vehicle pull-up space....
-
11B-503.3 Access aisle
Passenger drop-off and loading zones shall provide access aisles complying with Section 11B-503 adjacent and parallel to the vehicle pull-up space....
-
5.3 Transfer Sides Recommendations
5.3 Transfer Sides Recommendations...
-
4.6.5 PASSENGER LOADING ZONES
Passenger loading zones shall provide an access aisle at least 60 in (1525 mm) wide and 20 ft (6 m) long adjacent and parallel to the vehicle pull-up space (see Fig. 10)....
-
4.6.6 Passenger Loading Zones
Passenger loading zones shall provide an access aisle at least 60 in (1525 mm) wide and 20 ft (240 in)(6100 mm) long adjacent and parallel to the vehicle pull-up space (see Fig. 10)....
-
4.3.6 Reach Limits
4.3.6 Reach Limits Accommodation models were developed from the research findings for forward and side (lateral) reach in an empty 56 grams (2 oz.) cylinder (figure 4‒8) and a heavier...
-
Side-Hinged Door Ovens: ADA Standard Section 804.6.5.1
Side-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to the latch side of the oven door....
- Figure 404.2.4.1(f) Maneuvering Clearances at Manual Swinging Doors and Gates: Hinge Approach, Push Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(j) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Push Side – Drawing from the U.S. Access Board