Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
Search Results "Clear Floor Space"
-
305.5 Position
-
305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space....
-
305.7 Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach
-
306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
7(1) Usable kitchens
(1) Usable kitchens. Usable kitchens would meet section 100.205(c)(3)(iv) if:
-
7(1)(a)
(a) A clear floor space at least 30 inches by 48 inches that allows a parallel approach by a person in a wheelchair is provided at the range or cooktop and sink, and either a parallel or...
-
7(1)(b)
(b) Clearance between counters and all opposing base cabinets, countertops, appliances or walls is at least 40 inches.
-
7(1)(c)
kitchens with sink or range or cooktop at the base of the "U", a 60-inch turning radius is provided to allow parallel approach, or base cabinets are removable at that location to allow knee space...
-
7(2)(a)
Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Cabinets under lavatories are acceptable provided the bathroom has space...
-
7(2)(a)(ii)
(ii) Clear floor space is provided at fixtures as shown in Fig. 7 (a), (b), (c) and (d). Clear floor space at fixtures may overlap....
-
407.2.1.3 Clear Floor or Ground Space
407.2.1.3 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided at call controls. Advisory 407.2.1.3 Clear Floor or Ground Space....
-
7(2)(b)
(b) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Clear floor space beside tub may overlap with clear floor space...
-
7(2)(b)(i)
(i) Where the door swings into the bathroom, there is a clear space (approximately, 2' 6" by 4'0") within the room to position a wheelchair or other mobility aid clear of the path of the...
-
7(2)(b)(ii)
(ii) Where the door swings out, a clear space is provided within the bathroom for a person using a wheelchair or other mobility aid to position the wheelchair such that the person is allowed...
-
7(2)(b)(iii)
(iii) When both tub and shower fixtures are provided in the bathroom, at least one is made accessible. When two or more lavatories in a bathroom are provided, at least one is made...
-
7(2)(b)(iv)
(iv) Toilets are located within bathrooms in a manner that permit a grab bar to be installed on one side of the fixture. In locations where toilets are adjacent to walls or bathtubs,...
-
7(2)(b)(v)
The top of the fixture rim is a maximum height of 2'10" above the finished floor. If kneespace is provided below the vanity, the bottom of the apron is at least 2'3" above the floor....
-
7(2)(b)(vi)
(vi) Bathtubs and tub/showers located in the bathroom provide a clear access aisle adjacent to the lavatory that is at least 2'6" wide and extends for a length of 4'0" (measured from the...
-
7(2)(b)(vii)
A minimum clear floor space 2'6" wide by 4'0" should be available outside the stall. (See Figure 7(d).)...