The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. Figure 305.3 Clear Floor or Ground Space...
Search Results "Clear Floor Space"
-
305.3 Size
-
11B-305.3 Size
The clear floor or ground space shall be 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum. FIGURE 11B-305.3 CLEAR FLOOR OR GROUND SPACE...
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. Figure 305.3 Clear Floor or Ground Space...
-
1133A.2 Clear floor space
1133A.2 Clear floor space. Clear floor space at kitchens shall comply with the following:...
-
804.3.1 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for a forward approach shall be provided....
-
11B-602.2 Clear floor space
11B-602.2 Clear floor space. Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
-
1133A.2 Clear floor space
Clear floor space at kitchens shall comply with the following: A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows a parallel approach by a person in...
-
4.25.2 Clear Floor Space
A clear floor space at least 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 that allows either a forward or parallel approach by a person using a wheelchair shall be provided at...
-
4.25.2 CLEAR FLOOR SPACE
A clear floor space at least 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 that allows either a forward or parallel approach by a person using a wheelchair shall be provided at...
-
3.4.4 Clear Ground Space and Turning Space
Each viewing area that is required to be accessible by section 3.4.1 shall have a clear ground or floor space 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum positioned for either...
-
804.3.1 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for a forward approach shall be provided....
-
11B-611.2 Clear Floor Space
A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
11B-611.2 Clear Floor Space
A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
1008.4.2 Clear Floor or Ground Space
1008.4.2 Clear Floor or Ground Space. Clear floor or ground space complying with 305.2 and 305.3 shall be provided at play components....
-
305.1 General
Clear floor or ground space shall comply with 305....
-
305.1 General
Clear floor or ground space shall comply with 305....
-
305.1 General
Clear floor or ground space shall comply with 305....
-
305.1 General
Clear floor or ground space shall comply with 305....
-
4.16.2 CLEAR FLOOR SPACE
Clear floor space for water closets not in stalls shall comply with Fig. 28. Clear floor space may be arranged to allow either a left-handed or right-handed approach....
-
Refrigerator/Freezer: ADA Standard Section 804.6.6
Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1370 mm) maximum above the finish floor or ground....
-
11B-804.6.6 Refrigerator/freezer
Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1372 mm) maximum above the finish floor or ground....
-
11B-804.6.6 Refrigerator/freezer
Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1372 mm) maximum above the finish floor or ground....
-
11B-305.1 General
Clear floor or ground space shall comply with Section 11B-305....
-
11B-305.1 General
Clear floor or ground space shall comply with Section 11B-305. ...