Search Results "Clear Floor Space"
Commonly Searched Documents
- 305.3 Package Drop Box Clear Floor Space
-
805.3 Clear Floor or Ground Space
805.3 Clear Floor or Ground Space. A clear floor space complying with 305 shall be provided on each side of the bed....
-
4.1.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface slope, size, or location, the...
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADA Standards] 805.3 Clear Floor or Ground Space....
-
Door Swing [§304.4] and Other Space Requirements
Door Swing [§304.4] and Other Space Requirements Doors can swing into the turning space....
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory....
-
805.3 Clear Floor or Ground Space
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed....
-
805.3 Clear Floor or Ground Space
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed....
-
Example of a Single-User Bathroom (with Roll-in Shower)
Example of a Single-User Bathroom (with Roll-in Shower) Clear space required at any fixture can overlap required clear floor spaces, turning space, and door maneuvering space....
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
1991 / 1994 ADA Standards - Plan Review Tool - Plumbing Fixtures
1991 / 1994 ADA Standards - Plan Review Tool - Plumbing Fixtures Click here to view/download the pdf "1991 / 1994 ADA Standards - Plan Review Tool - Plumbing Fixtures" (323...
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
11B-809.10.4 Sufficient maneuvering space
Where doors swing into the toilet and bathing or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 (762 mm) inches by 48 inches (1219 mm) minimum shall...
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
4.7.9.2 Clear Floor or Ground Space
Clear floor or ground space 48 inches (1220 mm) by 30 inches (760 mm) oriented for a forward or parallel approach shall be provided for utility sinks required to meet 4.7.9....
-
4.2.4.1 SIZE AND APPROACH
The minimum clear floor or ground space required to accommodate a single, stationary wheelchair occupant is 30 in by 48 in (760 mm by 1220 mm) (see Fig. 4(a))....
-
4.6.7 Openings
Openings in the clear floor or ground space surface shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter....
-
Space Allowance and Reach Ranges [4.2]
Space at least 30 by 48 inches is the minimum required for a person using a wheelchair....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....