Where gangways connect to transition plates, landings specified by 405.7 shall not be required. 6....
Search Results "Elevator Landing"
Commonly Searched Documents
-
Boat Slips: ADA Standard Section 1003.2.1
-
11B-1003.2.1 Boat slips
The vertical distance is 10 feet (3050 mm) between the elevation where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level....
-
CIRCULATION PATH
[DSA-AC] An exterior or interior way of passage provided for pedestrian travel, including but not limited to, walks, hallways, courtyards, elevators, platform lifts, ramps, stairways, and...
-
CIRCULATION PATH
[DSA-AC] An exterior or interior way of passage provided for pedestrian travel, including but not limited to, walks, sidewalks, hallways, courtyards, elevators, platform lifts, ramps, stairways...
-
Attachment A: Violations Identified in the United States' Letter of Findings (Sept. 29, 2014)
[See subsections ...]
- SafePath VulcanLanding™ Rubber Transition Ramp
- Harmar TG400 Toe Guard Commercial Platform Lift
-
7(2)(a)
(a) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Cabinets under lavatories are acceptable provided the...
-
NOSING
The leading edge of treads of stairs and of landings at the top of stairway flights....
-
UFAS vs. ADAAG Comparison
Accessibility Standards (UFAS) (Requirements: Stricter than ADAAG) UFAS Section Description 4.1.2(5) Elevator...
-
Site
A parcel of land bounded by a property line or a designated portion of a public right-of-way....
-
SITE
A parcel of land bounded by a lot line or a designated portion of a public right-of-way....
-
III-6.2000 Alterations: Path of travel
It can include sidewalks, lobbies, corridors, rooms, and elevators. It also includes phones, restrooms, and drinking fountains serving the altered area....
-
Wet Conditions: ADA Standard Section 504.7
Section 504.7 covers the current ADA Standards for wet conditions at stairways.
-
11B-504.7 Wet conditions
Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
1009.7.2 Separation
The fire-resistance-rated exterior wall construction shall extend horizontally 10 feet (3048 mm) beyond the landing on either side of the landing or equivalent fire-resistance-rated construction...
-
Solutions for Accessibility: Problems Involving Lifts and Elevators
[See subsections ...]
- Ascension Virtuoso 5460F Vertical Permanently-Installed Wheelchair Lift
-
Gangway
A variable-sloped pedestrian walkway that links a fixed structure or land with a floating structure. Gangways that connect to vessels are not addressed by this document....
-
GANGWAY
[DSA-AC] A variable-sloped pedestrian walkway that links a fixed structure or land with a floating structure. Gangways that connect to vessels are not addressed by this code....
-
11B-407.4.5 Illumination
The level of illumination at the car controls, platform, car threshold and car landing sill shall be 5 foot candles (54 lux) minimum....
-
Guidelines for Requirement 2
covered by the Guidelines include, for example: accessible route(s); protruding objects; ground and floor surface treatments; parking and passenger loading zones; curb ramps; ramps; stairs; elevator...
- Garaventa Artira - Inclined Platform Wheelchair Lift for Curving Stairwyays