Public Right-of-Way
-
1009.3 Stairways
egress, a stairway between stories shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate an area of refuge within an enlarged floor-level landing...
-
1009.7 Exterior areas for assisted rescue
discharge does not include an accessible route from an exit located on the level of exit discharge to a public way, an exterior area of assisted rescue shall be provided on the exterior landing...
-
RISER
The upright part between two adjacent stair treads, between either an upper or lower landing and an adjacent stair tread, or between two adjacent landings....
-
11B-411.2.1.2.4 Display screen
Upon activation of the accessibility function button, the display screen shall display information including but not limited to, operating instructions, user input confirmation, elevator...
-
1133B.5.4.5
SECTION 1133B GENERAL ACCESSIBILITY FOR ENTRANCES, EXITS AND PATHS OF TRAVEL 1133B.5 Ramps. 1133B.5.4.5 Landing width. ...
-
1009.3.2 Submerged Depth
Where landings are required by 405.7, at least one landing shall be located 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
R407.6.4 Change in Direction
Ramps that change direction between runs at landings shall have a clear landing 1.5 m (5.0 ft) minimum by 1.5 m (5.0 ft) minimum....
-
Submerged Depth
Where the sloped entry has a running slope greater than 1:20 (5%), a landing at both the top and bottom of the ramp is required....
-
11B-1009.3.2 Submerged depth
Where landings are required by Section 11B-405.7, at least one landing shall be located 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
11B-1009.3.2 Submerged depth
Where landings are required by Section 11B-405.7, at least one landing shall be located 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
11B-505.2 Where required
At door landings, handrails are not required when the ramp run is less than 6 inches (152 mm) in rise or 72 inches (1829 mm) in length....
-
11B-405.9.1 Reserved.
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
1009.3.2 Submerged Depth
Where landings are required by 405.7, at least one landing shall be located 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
11B-233.3.1.2.6 Public housing facility site impracticality
The site impracticality tests in this section may be used to determine the number of required residential dwelling units with adaptable features in buildings without an elevator, located...
-
Accessible Ramp Features
Top landing part of walk 3. Bottom landing part of walk 4. Handrail height 34 to 38 inches 5. Edge protection...
-
11B-1009.3.2 Submerged depth
Where landings are required by Section 11B-405.7, at least one landing shall be located 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
1009.3.2 Submerged Depth
Where landings are required by 405.7, at least one landing shall be located 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
505.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
505.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
11B-505.10.1 Top and bottom extension at ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
11B-505.10.1 Top and bottom extension at ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
11B-411.2.2.2 Verbal identification
When the accessibility function button is pressed, verbal announcement of the car designation shall be provided at the elevator car entrance upon arrival....
-
505.10.2 Top Extension at Stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....