If the Forest Service builds a facility, even in remote areas or areas that are difficult to access (including wilderness), the facility must be accessible, with few exceptions....
Search Results "Elevator Building"
-
Do facilities in remote locations have to be accessible?
-
Cities and Counties: First Steps Toward Solving Common ADA Problems
Common Problems with New Construction and Alterations Ø It is very common for architects and contractors to follow only their local building codes, which may not provide the same...
-
CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS
Chapter 5 covers the current ADA Standards for general site and building elements that are required to be accessible.
-
Maneuvering Space
At least one maneuvering space must be provided on the same level as elevated play components....
-
GRADE (Adjacent Ground Elevation)
[DSA-AC] The lowest point of elevation of the finished surface of the ground, paving or sidewalk within the area between the building and the property line or, when the property line is...
-
GRADE (Adjacent Ground Elevation)
[DSA-AC] The lowest point of elevation of the finished surface of the ground, paving or sidewalk within the area between the building and the property line or, when the property line is...
-
11B-216.1 General
Building directories, menus, seat and row designations in assembly areas, occupant names, building addresses, and company names and logos shall not be required to comply with Section 11B...
-
Existing elevator cab size
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
-
Requirement 6 -- Reinforced Walls for Grab Bars
[See subsections ...]
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the...
-
11B-411.2.1.5.2 Color
Characters and symbols on buttons, where provided, shall be white on a black background.
-
11B-409.4.3 Platform to hoistway clearance
The clearance between the car platform and the edge of any landing sill shall be 1½ inch (38 mm) maximum.
-
1008.3.2.3 Transfer Supports
At least one means of support for transferring shall be provided. Advisory 1008.3.2.3 Transfer Supports. Transfer supports are required on transfer platforms and transfer steps to...
-
409.4.7.1 Type
A telephone and emergency signal device shall be provided in the car.
-
409.4.7.4 Cord
The telephone cord shall be 29 inches (735 mm) long minimum.
-
407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor.
-
409.4.7.3 Compartment
If the telephone or device is in a closed compartment, the compartment door hardware shall comply with 309.
-
409.4.7.2
The telephone and emergency signaling device shall comply with 309.3 and 309.4.
-
407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses.
-
11B-409.4.7.3 Compartment
If the telephone or device is in a closed compartment, the compartment door hardware shall comply with Section 11B-309 _|Operable Parts|_.
-
11B-409.4.7.4 Cord
The telephone cord shall be 29 inches (737 mm) long minimum.
-
11B-409.4.7.1 Type
A telephone and emergency signal device shall be provided in the car.
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor.