The clear space shall extend under the bed parallel to the long side and be adjacent to an accessible route....
Search Results "Latch Side Clearance"
Commonly Searched Documents
-
11B-806.2.3.1 Personal lift device floor space
-
11B-806.2.3.1 Personal lift device floor space
The clear space shall extend under the bed parallel to the long side and be adjacent to an accessible route....
- Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach – Drawing from the U.S. Access Board
- Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach – Drawing from the U.S. Access Board
-
FIGURE INDEX
in an Alcove, Forward Approach Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach Figure 306.2 Toe Clearance Figure 306.3 Knee Clearance Figure...
-
404.2.3 Clear Width
In alterations, a projection of 5/8 inch (16 mm) maximum into the required clear width shall be permitted for the latch side stop. 2....
-
11B-404.2.3 Clear width
In alterations, a projection of 5/8 inch (15.9 mm) maximum into the required clear width shall be permitted for the latch side stop. 2. ...
-
404.2.3 Clear Width
In alterations, a projection of 5/8 inch (16 mm) maximum into the required clear width shall be permitted for the latch side stop. 2....
-
Signage
Requirements: Signs that are provided for all permanent rooms and spaces in the lodging facility must be mounted on the wall (not the door) adjacent to the latch side of the door and...
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
- Boost Your Business - Chapter 12 - Elevators
-
Chapter 3: Building Blocks
These requirements address floor and ground surfaces (302), changes in level (303), wheelchair turning space (304), clear floor or ground space (305), knee and toe clearance (306), protruding...
-
A4.13.11(2) Sliding or folding doors
(2) Sliding or folding doors: Force applied parallel to the door at the door pull or latch....
-
A4.13.11(2) Sliding or folding doors
(2) Sliding or folding doors: Force applied parallel to the door at the door pull or latch....
-
1133B.2.3.2
is greater than 10 and it is determined that compliance with Section 1133B.2.3 would create an unreasonable hardship, a projection of 5/8 inch (16 mm) maximum will be permitted for the latch...
-
11B-902.4.1 Clear floor or ground space
Knee and toe clearance complying with Section 11B-306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
4.25.4 Hardware
Touch latches and U-shaped pulls are acceptable....
-
4.25.4 HARDWARE
Touch latches and U-shaped pulls are acceptable....
-
Wall-Mounted Objects
Wing walls, side partitions, and alcoves or recesses can be used for elements such as drinking fountains with their bottom edges above 27 inches....
- Mockett DH2 Door Handle Installation
-
Trash and Recycling Receptacles [1011.2 and 1011.3]
The operable parts of trash and recycling containers, such as handles or latches, must be between 15 and 48 inches above the ground....
-
229 Windows
Commenters generally supported this provision but some commenters asked whether the maximum five-pounds (5 lbs.) of force requirement of section 309 applies to the window latch itself or...