Doors to accessible bathrooms shall comply with 4.13. Doors shall not swing into the floor space required for any fixture.
Search Results "Clear Width at Turn"
-
4.23.2 Doors
-
4.23.2 DOORS
Doors to accessible bathrooms shall comply with 4.13. Doors shall not swing into the floor space required for any fixture.
-
11B-604.9.2 Clearance
11B-604.9.2 Clearance. Clearance around a water closet shall comply with Section 11B-604.3.
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
11B-604.9.2 Clearance
Clearance around a water closet shall comply with Section 11B-604.3.
-
BABY CHANGE
Hello: I am the first person to watch the vedio
-
1134A.6, Item 1.2
A water closet may project a maximum of 12 inches (305 mm) into the opening, provided that a minimum of 36 inches (914 mm) clear space is maintained between the water closet and the shower...
-
806 Transient Lodging Guest Rooms
The Department’s drawings are sample plans, showing the layout of the space, relationship of elements to each other, and required clear floor and turning spaces....
-
Exterior Routes
width of walking surface. 11B-403.5.1 Contrasting stripe on upper approach and all treads. 11B-504.4.1 No open risers...
-
Exterior Routes
width of walking surface. 11B-403.5.1 Contrasting stripe on upper approach and all treads. 11B-504.4.1 No open risers...
-
1134A.6, Item 1.2
A water closet may project a maximum of 12 inches (305 mm) into the opening provided that a minimum of 36 inches (914 mm) clear space is maintained between the water closet and the shower...
-
Accessible Sidewalks 2: Pedestrians with Ambulatory Impairments
Requires the Registered User plan or above. Login!
-
5.1.7 Surface
The surface of the clear ground space shall be firm and stable....
-
4.34.5.1 DOORS
Doors shall not swing into the clear floor space required for any fixture....
-
11B-604.3.2 Overlap
clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear...
-
Fixtures
Fixtures TAS 604.3.2 also allows the clear floor space and clearances required at other “fixtures” to overlap the water closet clearance....
-
Top and Bottom Extension at Ramps: ADA Standard Section 505.10.1
Section 505.10.1 covers the current ADA Standards for the top and bottom handrail extensions at ramps.
-
Path Width
Section 4.2.1 of the ADAAG requires a minimum clear width of 0.815 m (32 inches) at a point, and 0.915 m (36 inches) continuously, for single wheelchair passage....
-
Areas of Refuge [IBC §1007.6 (2003), §1003.2.13.5 (2000)]
Areas of refuge are fire-resistance rated and smoke protected areas where those unable to use stairs can register a call for evacuation assistance and await instructions or...
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADAS] 805.3 Clear Floor or Ground Space. ...
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADAS] 805.3 Clear Floor or Ground Space....
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADA Standards] 805.3 Clear Floor or Ground Space....