Ramps not subject to the exception to 405.5 shall be designed to maintain a 36 inch (915 mm) minimum clear width when handrails are installed....
Search Results "Clear Width at Turn"
-
11B-405.8 Handrails
-
11B-405.8 Handrails
Ramps not subject to the exception to 405.5 shall be designed to maintain a 36 inch (915 mm) minimum clear width when handrails are installed....
-
11B-805 Medical care and long-term care facilities
Exception: General exam rooms in non-emergency settings may provide clear space on only one side of beds, gurneys and exam tables. 11B-805.4.2 Equipment....
-
1012.3 Other Vehicles
Parking spaces for vehicles, other than recreational vehicles, shall be 16 feet (4880 mm) wide minimum. EXCEPTION: Where two adjacent parking spaces are provided for vehicles,...
-
1012.3 Other Vehicles
Parking spaces for vehicles, other than recreational vehicles, shall be 16 feet (4880 mm) wide minimum. EXCEPTION: Where two adjacent parking spaces are provided for vehicles,...
-
Van Space: Wider Access Aisle
Van Space: Wider Access Aisle
-
11B-405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
11B-405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
11B-804.6.6 Refrigerator/freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
11B-804.6.6 Refrigerator/freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
11B-804.6.6 Refrigerator/freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
804.6.6 Refrigerator/Freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
804.6.6 Refrigerator/Freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
804.6.6 Refrigerator/Freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
- Pilot Rock Smoker's Cease Fire Ash Receptacle
-
1014.2.1.1.1 Surface
The surface of the clear ground space shall be firm and stable....
-
1014.2.1.1.1 Surface
The surface of the clear ground space shall be firm and stable....
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...
-
606.2 Clear Floor Space (Exception 3)
606.2 Clear Floor Space (Exception 3) This section requires clear floor space positioned for a forward approach and knee and toe clearance to be provided at lavatories and sinks....
-
Features of Accessible Parking Spaces
If the accessible route is located in front of the parking space, install wheel stops to keep vehicles from reducing the clear width of the accessible route below 36 inches. 3....
-
902.4.1 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for forward approach shall be provided....