606.2 Clear Floor Space. A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided. EXCEPTIONS: 1....
Search Results "Clear Width at Turn"
-
606.2 Clear Floor Space
-
M13
For each type of dispenser, receptacle, or equipment, is there clear floor space at least 30 inches wide x 48 inches long adjacent to the control or dispenser (positioned either parallel...
- Access Board: Clear Floor or Ground Space
-
H12
For at least one of each type of dispenser, receptacle, or equipment, is there clear floor space at least 30 inches wide x 48 inches long adjacent to the control or dispenser (positioned...
-
§ 38.107(a)(1)
(1) The minimum clear floor area shall be 35 inches by 60 inches....
-
Forward Reach [4.2.5]
Forward reaches are measured to the edge of available clear floor space. This accommodates high and low reaches and assumes some forward bending....
-
Viewing Scopes [1011.2, 1011.3, and 1011.8]
At viewing scopes used from a seated position, a minimum of 36 by 48 inches of clear ground space positioned for a forward approach to the viewing scope must be provided....
-
11B-606.2 Clear floor space
11B-606.2 Clear floor space....
-
606.2 Clear Floor Space
A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided....
- Access Board: Tactile Sign Clear Floor Space
-
11B-813.2.1.2 Clearance
A 36 inches minimum (914 mm) width side clearance shall be provided along the entire length of one side of adult changing tables....
-
11B-809.10.7.1 Floor space
Exception: The 48-inch (1219 mm) minimum clear width may be reduced to 36 inches (914 mm) minimum for lavatories, cabinets, wing walls, or privacy walls located immediately adjacent to a...
-
604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets...
-
4.1.2(5)(a)
(a) If parking spaces are provided for self-parking by employees or visitors, or both, then accessible spaces complying with 4.6 shall be provided in each such parking area in...
-
A4.6.3 Parking Spaces
The increasing use of vans with side-mounted lifts or ramps by persons with disabilities has necessitated some revisions in specifications for parking spaces and adjacent access...
-
A4.6.3 PARKING SPACES
High-top vans, which disabled people or transportation services often use, require higher clearances in parking garages than automobiles. When optional van spaces are provided within...
-
604.8.1.1 Size
604.8.1.1 Size. Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall...
-
604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets...
-
1134A.8, Item 5
5. Finished floor. The finished floor beneath the lavatory shall be extended to the wall.
-
A4.33.2 Size of Wheelchair Locations
Spaces large enough for two wheelchairs allow people who are coming to a performance together to sit together.
-
A4.33.2 SIZE OF WHEELCHAIR LOCATIONS
Spaces large enough for two wheelchairs allow people who are coming to a performance together to sit together.
-
1134A.8, Item 5
5. Finished floor. The finished floor beneath the lavatory shall be extended to the wall.
-
Priority 1: Approach & Entrance
Word Fillable Form (1.5MB) Word Non-Fillable Form (1.3MB) PDF Non-Fillable Form (0.8MB)
-
Beds: ADA Standard Section 232.2.1.1
Section 232.2.1.1 covers scoping requirements in the current ADA Standards for beds.