Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear...
Search Results "Ground Floor"
-
11B-604.3.1 Size
-
11B-604.3.1 Size
11B-604.3.1 Size. Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured...
-
§ 38.95(a)(2) Exception
(2) Exception. If level-entry boarding, portable or platform lifts, ramps or bridge plates meeting the applicable requirements of this section are provided on station platforms or...
-
§ 38.93(d)(3) Exception
(3) Exception. Where platform set-backs do not allow the horizontal gap or vertical alignment specified in paragraph (d)(1) or (d)(2) of this section, car, platform or portable lifts...
-
4.21.2 SIZE AND CLEARANCES
Shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
- GameTime Roller Slide
- SlabGasket™ Expansion Joint Replacement Solution
- GameTime Adaptive Swing Seat
-
11B-604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor...
-
11B-604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor...
-
4.21.2 Size and Clearances
Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
Q5.) What dimensions and conditions can practitioners reasonably consider to be compliant when the conditions, as constructed, do not meet the technical requirements exactly and there are no official, published, industry-developed tolerances?
A5.) This is the most difficult question and the most subject to varying opinions. Sloped concrete and asphalt surfaces are an excellent example of this problem. To our...
-
Rough Grade Site Inspection
ROUGH GRADE SITE INSPECTION Locate and verify the plan specified accessible routes from existing public sidewalks, accessible parking...
-
Rough Grade Site Inspection
ROUGH GRADE SITE INSPECTION Locate and verify the plan specified accessible routes from existing public sidewalks, accessible parking...
-
Accessible Passenger Loading Zones [§503]
Accessible Passenger Loading Zones [§503] Requirements for accessible passenger loading zones address vehicle pull-up spaces and access aisles, including their dimensions,...
- Kompan, Inc. Elements Play Structures Ridge ELE500003
-
ATM Clear Floor or Ground Space
Sections 707.2 and 707.3 address clear floor or ground space requirements and operable parts, respectively. These provisions include exceptions for drive-up only ATMs....
-
Plumbing/Restrooms
PLUMBING/RESTROOMS Turning space within the room 11B-603 Door swing not in clear floor space of any fixture (except...
-
4. Assess During the Planning, Installation and Maintenance Phases
The clear ground space at the transfer system....
-
31.1 Q. Can a water closet (toilet) be located in an alcove with a wing wall?
Yes, as long as the necessary clear floor space shown in Figure 7(a) is provided....
- ACCESSMAT® - EN - Beach accessibility mats
-
Clear Floor or Ground Space [4.31.2], Mounting Height [4.31.3]
Clear Floor or Ground Space [4.31.2], Mounting Height [4.31.3] Generally, access can be provided with either a forward or side approach....
-
4.10.12(2)
The call button for the main entry floor shall be designated by a raised star at the left of the floor designation (see Fig. 23(a))....