Where wheelchair space entry and exit is provided at only one end (front or rear) the wheelchair space shall be 48 inches (1220 mm) deep minimum.
Search Results "Patient Change Area"
-
M303.2.3.1 Front or Rear Entry
-
M305.3 Standing Supports
Standing supports shall provide continuous support throughout use of the diagnostic equipment and shall comply with M305.3.
-
M303.2.3.3 Side Entry
Where wheelchair space entry is only from the side, the wheelchair space shall be 60 inches (1525 mm) deep minimum.
-
M303.2.3.2 Pass Through Entry
Where wheelchair space entry and exit permits pass through from one end to the other, the wheelchair space shall be 40 inches deep (1015 mm) minimum.
-
M304.2.2 Standing Supports
Standing supports shall be provided on two sides of the standing surface and shall comply with M305.3. EXCEPTION: Diagnostic equipment with entry and exit permitting pass-through...
-
Physical Access
Resources found at http://www.hfcdihp.org/products.html Choosing and Negotiating an Accessible Facility Location Improving Accessibility with Limited...
-
M304.3 Standing Supports
Standing supports shall be provided on each side of the standing surface and shall comply with M305.3.
-
M305.3 Standing Supports
Standing supports shall provide continuous support throughout use of the diagnostic equipment and shall comply with M305.3.
-
T210.4 Location
Wheelchair spaces shall be located as near as practicable to doorways that provide a means of accessible boarding and alighting.
-
T215.2.3 Doorways
Doorways that provide a means of accessible boarding and alighting shall be identified on the exterior of the non-rail vehicle by the International Symbol of Accessibility complying...
-
K4
K4. If built-in food, drink, condiment, and tableware dispensers are provided, are dispensers and operating controls mounted no higher than 54 inches above the floor if clear floor...
-
11B-405.5 Clear width
Within employee work areas, the required clear width of ramps that are a part of common use circulation paths shall be permitted to be decreased by work area equipment provided that the...
-
11B-405.5 Clear width
Exceptions: Within employee work areas, the required clear width of ramps that are a part of common use circulation paths shall be permitted to be decreased by work area equipment...
-
11B-405.5 Clear width
Within employee work areas, the required clear width of ramps that are a part of common use circulation paths shall be permitted to be decreased by work area equipment provided that the...
-
Residential Facilities: ADA Standard Section 203.8
Section 203.8 covers scoping requirements of general exceptions for residential facilities in the most current ADA Standards.
- Ronick Matting Systems BaseMat 300 Entrance Floor Mat
-
16. If a play surface is replaced with an accessible surface and the existing ground level play components are not accessible, do the components need to be replaced?
If the alteration to the play area only involves the surfacing, only the surface along accessible routes, clear floor or ground spaces, and maneuvering spaces must comply with the ASTM F...
-
11B-221.2.1.1 General seating
TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS NUMBER OF SEATS MINIMUM NUMBER OF REQUIRED WHEELCHAIR SPACES...
-
11B-221.2.1.1 General seating
TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS Number Of Seats Minimum Number Of Required Wheelchair Spaces 4 to 25 1...
-
11B-221.2.1.1 General seating
TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS NUMBER OF SEATS MINIMUM NUMBER OF REQUIRED WHEELCHAIR SPACES...
-
Approach, Enter, and Exit
Approach, Enter, and Exit Employee work areas are required by TAS 203.9 to be designed and constructed so that individuals with disabilities can approach, enter, and exit the work area...
-
M301.4.2 Clearance Around Base
The base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
M301.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
M301.4.2 Clearance Around Base