Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum...
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
-
11B-407.4.6.1 Location
-
11B-602.2 Clear floor space
Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground...
-
11B-610.2 Bathtub seats
The top of bathtub seats shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
11B-602.2 Clear floor space
Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground...
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
11B-1003.3.2 Boarding pier clearances
Every 10 feet (3048 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum. Exceptions: 1. ...
-
1003.3.2 Boarding Pier Clearances
Every 10 feet (3050 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1525 mm) wide minimum. EXCEPTIONS: 1....
-
1003.3.2 Boarding Pier Clearances
Every 10 feet (3050 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1525 mm) wide minimum. EXCEPTIONS: 1....
-
For More Information
For More Information Technical Information Regarding Web Accessibility For technical assistance regarding Section 508 Standards and how to make web pages accessible to people with...
-
1.1 Conditions for an Exception
Where compliance with the technical provision is not practicable due to terrain. Condition for an Exception 2....
- Symmetry Limited Use/Limited Application (LU/LA) Elevator
-
XI. Overview of Americans with Disabilities Act Accessibility Guidelines for New Construction and Alterations
They also have specific technical standards for restaurants, medical care facilities, mercantile facilities, libraries, and transient lodging (such as hotels and shelters). ...
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
General: ADA Standard Section 233.1
Section 233 of the ADA Standards covers information in the current ADA Standards on scoping requirements for residential facilities.
-
ADA Standards for Accessible Design Pocket Guide: ADA Standard Section 2010
The complete guide to the 2010 ADA Standards for Accessible Design with notes provided by national accessibility experts Evan Terry Associates
-
11B-809.12 Electrical receptacles, controls and switches
branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no obstruction, 48 inches (1219 mm) maximum...
-
11B-809.12 Electrical receptacles, controls and switches
branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no obstruction, 48 inches (1219 mm) maximum...
-
M301.3.1 Transfer Supports
C) The maximum distance from the transfer surface to either the transfer support or the positioning support is 1.5 inches....
-
11B-203.1 General
Sites, buildings, facilities, and elements are exempt from these requirements to the extent specified by 11B-203....
-
E202.1 General
ICT shall be exempt from compliance with the Revised 508 Standards to the extent specified by E202....
-
11B-203.1 General
Sites, buildings, facilities, and elements are exempt from these requirements to the extent specified by 11B-203....
-
11B-203.1 General
Sites, buildings, facilities, and elements are exempt from these requirements to the extent specified by 11B-203....