Cover: Fabricated of #22 ga stainless steel #4 satin finish with embossed handles on each side and sloped top. Bottom Panel: #22 ga hinged and locked for removal of contents....
Search Results "Counter Slope"
Commonly Searched Documents
- AJW Architectural Products U590 1.6 Gallon Sanitary Napkin Disposal w/ Keyed Access Panel - Surface Mounted
-
Shared Use Paths: ADA Standard Section 2.
, which address access to sidewalks, streets, and other pedestrian facilities, provide requirements for pedestrian access routes, including specifications for route width, grade, cross slope...
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
Test No. 1 -- Individual Building Test may only be used if the site has terrain over 15 percent slope. Test No. 3 -- Unusual Characteristics Test may be used if applicable....
-
11B-810.2.3 Connection
boarding and alighting areas shall provide a detectable transition between the boarding/alighting area and the roadway; the detectable transition shall consist of a curb with the face sloped...
-
303.3 Beveled
Changes in level between 1/4 inch (6.4 mm) high minimum and 1/2 inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 303.3 Beveled....
-
Tent Pads and Tent Platforms [1013]
Tent pads and tent platforms must comply with the technical requirements for clear ground space and slope. Tent platforms must also comply with the technical requirements for height....
-
10.1 Q. Is it necessary to have an accessible path of travel from a subterranean garage to single-story covered multifamily dwellings built on top of the garage?
This may be provided either by a properly sloped ramp leading from the below grade parking to grade level, or by means of an elevator from the parking garage to the dwelling units....
-
4.6.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
1013.1 General
The technical requirements address the clear ground space around tent pads and tent platforms (1013.2); the slope of tent pads, tent platforms, and clear ground spaces (1013.2); and the...
-
11B-810.2.3 Connection
boarding and alighting areas shall provide a detectable transition between the boarding/alighting area and the roadway; the detectable transition shall consist of a curb with the face sloped...
-
11B-810.2.3 Connection
boarding and alighting areas shall provide a detectable transition between the boarding/alighting area and the roadway; the detectable transition shall consist of a curb with the face sloped...
-
11B-206.2.1 Site arrival points
(1) Newly constructed or altered streets, roads, and highways must contain curb ramps or other sloped areas at any intersection having curbs or other barriers to entry from a street...
-
Readily Achievable Barrier Removal
For example, where there is not enough space to install a ramp with a slope that complies with the Standards, a business may install a ramp with a slightly steeper slope....
-
1131B.2, Item 1
Vehicle standing spaces and access aisles shall be level with surface slopes not exceeding one unit vertical in 50 units horizontal (2-percent slope) in all directions....
-
8.2.1 Participants
Moderately-severe, gently sloping hearing loss: PTA is greater than 41 dB HL with threshold at 2000 Hz between 55 and 60 dB HL). 4....
-
1010.1.5 Floor elevation
Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit vertical in 12 units horizontal (2-percent slope)....
-
4. Comparison of Proposed Technical Provisions Applicable to Shared Use Paths and AASHTO Guide
R302.6 Cross Slope. Except as provided in R302.6.1 and R302.6.2, the cross slope of pedestrian access routes shall be 2 percent maximum....
-
MAKING THE BUILT ENVIRONMENT ACCESSIBLE
no access aisle to allow deployment of a van’s wheelchair lift, steps at a facility’s entrance or within its serving or selling space, aisles too narrow to accommodate mobility devices, counters...
-
205.1 General
Where two or more outlets are provided in a kitchen above a length of counter top that is uninterrupted by a sink or appliance, one outlet shall not be required to comply with 309. 4....
-
20. DESIGN AND CONSTRUCTION STANDARDS
., signage, front desk counter) for any Brand, it shall ensure that such designs comply with the ADA Standards....
-
Base Support [No specific provision—affects M303.2.4]
The subcommittee also discussed adding an allowance for a sloped region at the base of the gantry....
-
Individuals with Partial or Total Vision Loss
In addition, their path of travel may be influenced by subtle changes in grade or cross slope that are not readily detected by others, or by overhead and overhanging branches, etc., and...
-
11B-303.3 Beveled
Changes in level between ¼ inch (6.4 mm) high minimum and ½ inch (12.7 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 11B-303.3 Beveled....
- Diversified Woodcrafts Forward Vision ADA Workstation 2956KF-L-ADA