clearance under the front edge of the lavatory, the top of the bowl mounted no higher than 34 inches above the floor, a 27-inch-high clearance for knee space extending at least 8 inches from...
Search Results "Assurances from Contractors"
-
3. Lavatory knee clearance
-
607.4.2.1 Back Wall
Each grab bar shall be 24 inches (610 mm) long minimum and shall be installed 24 inches (610 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall....
-
604.9.1 Location
The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430...
-
703.4.1 Height Above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
About the Author
Scott earned a bachelor’s degree in civil and environmental engineering from the Uni-versity of Wisconsin at Madison and a master’s degree in civil engineering from Montana State University...
-
703.4.1 Height Above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
407.2.2.2 Visible Signals
Signals shall be visible from the floor area adjacent to the hall call button. EXCEPTIONS: 1....
-
Adjustable height protocol
Adjustable height protocol: From initial setup, only the height of the platform was adjusted incrementally: higher (Figure 3) and lower than the subject’s seat. ...
-
Section 2. Slope
., an entrance and a passenger loading zone) are determined from a topographical map....
-
604.9.1 Location
The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430...
-
Comments
Most of the comments on these issues were from the disability community, and they unanimously recommended that GFE be required....
-
11B-604.9.1 Location
The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432...
-
CIRCULATION PATH
Whenever the accessible route diverges from the regular circulation path signage may be required to identify the departure from the regular route if not obvious.◼...
-
Verify Rough Plumbing
Location of toilet flanges from walls. 11B-604.2 Location of lavatory traps from side walls. 11B-606.6 Location of...
-
Verify Rough Plumbing
Location of toilet flanges from walls. 11B-604.2 Location of lavatory traps from side walls. 11B-606.6 Location of...
-
Where Service Animals Are Allowed
For example, in a hospital it would be inappropriate to exclude a service animal from areas such as patient rooms, clinics, cafeterias, or examination rooms....
-
4.3.10* EGRESS
Where fire code provisions require more than one means of egress from any space or room, then more than one accessible means of egress shall also be provided for handicapped people....
-
604.2 Location
The centerline of the water closet shall be 16 inches (405 mm) minimum to 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430...
-
M302.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
M301.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
§ 38.97(a)
compartment shall be placed to permit sufficient turning and maneuvering space for wheelchairs and other mobility aids to reach a seating location, complying with §38.95(d) of this part, from...
-
§ 38.115(a)
compartment shall be placed to permit sufficient turning and maneuvering space for wheelchairs and other mobility aids to reach a seating location, complying with §38.125(d) of this part, from...
-
1.9.1.8 Adopting agency identification
ETA Editor's Note Sections from the California Building Code Chapter 1 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
11B-607.4.2.1 Back wall
Each grab bar shall be 24 inches (610 mm) long minimum and shall be installed 24 inches (610 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall....