ETA Editor's Note The implication of 11B-404.3.2 is that power-assist devices (ANSI/BHMA A156.19) cannot substitute for required door maneuvering clearances, even if standby power is...
Search Results "Maneuvering Space"
-
11B-404.3.2 Maneuvering clearance
-
1010.1.5 Floor elevation
Doors serving equipment spaces not required to be accessible in accordance with Section 11B-203.5 and serving an occupant load of five or less shall be permitted to have a landing on one...
-
Size: ADA Standard Section 305.3
Section 305.3 covers the current ADA Standards for the required size of compliant clear floor or ground space.
-
General: ADA Standard Section 305.1
Section 305.1 of the ADA Standards covers information in the current ADA Standards for clear floor or ground space.
-
General: ADA Standard Section 304.1
Section 304.1 of the ADA Standards covers information in the current ADA Standards for turning space.
-
Overlap: ADA Standard Section 603.2.2
Section 603.2.2 covers the current ADA Standards for overlapping clear floor space at fixtures and turning spaces in toilet and bathing rooms.
-
General: ADA Standard Section 306.1
Section 306.1 of the ADA Standards covers information in the current ADA Standards for knee and toe clearance.
-
11B-306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with Section 11B-306....
-
11B-306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with Section 11B-306....
-
31.1 Q. Can a water closet (toilet) be located in an alcove with a wing wall?
Yes, as long as the necessary clear floor space shown in Figure 7(a) is provided....
-
11B-604.8.1.1 Size
Wheelchair accessible compartments shall additionally provide maneuvering space complying with Section 11B-604.8.1.1.1, 11B-604.8.1.1.2, or 11B-604.8.1.1.3, as applicable....
-
Turning Space: ADA Standard Section 805.2
Turning space complying with 304 shall be provided within the room....
-
11B-604.8.1.1 Size
Wheelchair accessible compartments shall additionally provide maneuvering space complying with Section 11B-604.8.1.1.1, 11B-604.8.1.1.2, or 11B-604.8.1.1.3, as applicable....
-
Wheelchair Storage Space: ADA Standard Section 1002.6.3
Wheelchair storage spaces complying with 305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress or accessible...
-
Clear Floor Space: ADA Standard Section 808.3
Each jury box and witness stand shall have, within its defined area, clear floor space complying with 305....
-
Clear Floor or Ground Space: ADA Standard Section 804.3.1
A clear floor space complying with 305 positioned for a forward approach shall be provided....
-
Clear Floor Space: ADA Standard Section 606.2
Section 606.2 covers the current ADA Standards for clear floor space at lavatories and sinks.
-
405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area....
-
405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area....
-
Space
A definable area, such as a room, toilet room, hall, assembly area, entrance, storage room, alcove, courtyard, or lobby.
-
SPACE
[DSA-AC] A definable area, such as a room, toilet room, hall, assembly area, entrance, storage room, alcove, courtyard, or lobby.
-
SPACE
[DSA-AC] A definable area, such as a room, toilet room, hall, assembly area, entrance, storage room, alcove, courtyard, or lobby.
-
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls.
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls....
-
405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area....