Knee and toe clearance shall be provided and comply with Section 11B-306.
Search Results "Adaptable"
-
11B-809.10.8.4 Knee and toe clearance
-
11B-809.10.7.3 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom...
-
SECTION 504 OF THE REHABILITATION ACT OF 1973 POLICY INTERPRETATION NO. 5
SECTION 504 OF THE REHABILITATION ACT OF 1973 POLICY INTERPRETATION NO. 5 Subject: Participation of Handicapped Students in Contact Sports. Policy...
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
In elevator buildings, public housing facilities with multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story...
-
11B-809.10.5 Bathtubs
Bathtubs required by Section 11B-809.10 shall comply with this section.
-
11B-809.9.5 Lower shelving
Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor.
-
11B-228.2 Mail boxes
boxes complying with Section 11B-309 shall be provided for each residential dwelling unit required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4 and adaptable...
-
11B-228.2 Mail boxes
boxes complying with Section 11B-309 shall be provided for each residential dwelling unit required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4 and adaptable...
-
11B-228.2 Mail boxes
boxes complying with Section 11B-309 shall be provided for each residential dwelling unit required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4 and adaptable...
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and...
-
11B-809.8.2 Door opening force
Doors shall comply with Section 11B-404.2.9. Exception: The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum.
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum.
-
11B-809.10.2 Number of complying bathrooms and fixtures
Each accessible dwelling unit with adaptable features where sanitary facilities are located within the unit or suite must provide at least one bathroom complying with the definition of “...
-
1134A.4 Sufficient maneuvering space
Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door, use the...
-
1134A.4 Sufficient maneuvering space
Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door, use the...
-
1134A.4 Sufficient maneuvering space
Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door, use the...
-
§100.205(c)(3)(i)
(i) An accessible route into and through the covered dwelling unit;
-
11B-809.7.2 Changes in level
Changes in level shall comply with Sections 11B-303.2 and 11B-303.3. Ramps complying with Section 11B-405, elevators complying with Section 11B-407 or platform lifts complying with...
-
11B-809.7.1 Width
The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors.
-
11B-809.10.6 Showers
Showers required by Section 11B-809.10 shall comply with this section.
-
11B-809.9.6 Controls
Controls for faucets shall comply with Section 11B-309.1. Hand-operated metering faucets shall remain open for 10 seconds minimum.
-
11B-809.12 Electrical receptacles, controls and switches
Electrical receptacles on branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no...
-
11B-233.3.1.2.6.2 Test number one, individual building test
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: 1. The slopes of the undisturbed site...
-
11B-233.3.1.2.6.3 Test number two, site analysis test
For a site having multiple buildings, or a site with a single building with multiple entrances, it is not required to provide a building entrance on an accessible route to all ground...