Unusual characteristics include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to other similar requirements of law or...
Search Results "Adaptable"
Commonly Searched Documents
-
11B-233.3.1.2.6.4 Test number three, unusual characteristics test
-
11B-233.3.4.1 Alterations to vacated buildings
Where a building is vacated for the purposes of alteration, and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling...
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
building with one common (lobby) entrance, located on a site with difficult terrain conditions or unusual characteristics: All ground floor units in non-elevator buildings shall be adaptable...
-
§100.205(c)(3)(iii)
(iii) Reinforcements in bathroom walls to allow later installation of grab bars around the toilet, tub, shower, stall and shower seat, where such facilities are provided; and
-
11B-233.3.5 Dispersion
Residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4 and residential dwelling units required to provide communication...
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length...
-
11B-809.9.3 Removable base cabinets
Knee and toe space complying with Section 11B-306 shall be provided at sinks and work surfaces required to comply with Section 11B-809.9.4. Exception: Removable base cabinets...
- SPORTS 'N SPOKES
-
11B-233.3.1.2.5 Public housing facility site impracticality
The number of adaptable residential dwelling units required in non-elevator building public housing facilities shall be determined in accordance with Chapter 11A, Section 1150A.1....
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory.
-
Universal Design in Practice
Select Adaptable Products 6. Coordinate with All the Players 7. Think About How People Will USE It 8. Design With Everyone In Mind 9. How Will It Age? 10....
-
11B-233.3.1.2.6 Public housing facility site impracticality
The site impracticality tests in this section may be used to determine the number of required residential dwelling units with adaptable features in buildings without an elevator, located...
- Easy Access Chicago
- Northeast Passage Living Beyond Disability
-
11B-233.3.1.2.6 Public housing facility site impracticality
The number of adaptable residential dwelling units required in non-elevator building public housing facilities shall be determined in accordance with Chapter 11A, Section 1150A.1....
- DOE Dear Colleague" Letter: Equal Access to Extracurricular Athletics for Students with Disabilities (Jan. 25, 2013)
- Gateway to Gold Mobile App for U.S. Paralympics
-
7(2)(b)(iii)
(iii) When both tub and shower fixtures are provided in the bathroom, at least one is made accessible. When two or more lavatories in a bathroom are provided, at least one is made...
-
7(2)(b)(i)
(i) Where the door swings into the bathroom, there is a clear space (approximately, 2' 6" by 4'0") within the room to position a wheelchair or other mobility aid clear of the path of...
-
11B-809.8 Doors
Primary entry doors, required exit doors, secondary exterior doors and interior doors intended for user passage shall comply with this section and Section 11B-404.2. Doors to small...
-
Changes in Level within a Dwelling Unit
The Department believes that the installation of a ramp or deck in order to make a sunken room accessible is the type of later adaptation that easily can be made by a tenant....
-
30.1 Q. Would it be acceptable to use removable base cabinets beneath a wall-hung lavatory where a parallel approach is not possible?
A. Yes. The space under and around the cabinet should be finished prior to installation. For example, the tile or other floor finish must extend under the removable base cabinet.
-
29.1 Q. Is it acceptable to design a bathroom with an in-swinging 2'10 door which can be retrofitted to swing out in order to provide the necessary clear floor space in the bathroom?
A. No. The requirements in the Guidelines must be included at the time of construction. Thus, for a bathroom, there must be sufficient maneuvering space and clear floor space so that...
-
7(2)(a)(i)
(i) Sufficient maneuvering space is provided within the bathroom for a person using a wheelchair or other mobility aid to enter and close the door, use the fixtures, reopen the door...