Signage indicating special accessibility provisions shall be provided as shown: Each door providing access to an area of refuge from an adjacent floor area shall be identified by a...
Search Results "Accessible Means of Egress"
Commonly Searched Documents
-
1009.9 Signage
-
1009.3 Stairways
In order to be considered part of an accessible means of egress, a stairway between stories shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate...
-
1009.5 Platform lifts
Platform lifts shall be permitted to serve as part of an accessible means of egress where allowed as part of a required accessible route in Chapter 11A, Sections 1121A and 1124A.11, or Chapter...
-
1009.5 Platform lifts
Platform lifts shall be permitted to serve as part of an accessible means of egress where allowed as part of a required accessible route in Chapter 11A, Sections 1121A and 1124A.11, or Chapter...
-
1007.2, Item 4
4. Exterior exit stairways complying with Sections 1007.3 and 1026 and serving levels other than the level of exit discharge, and Chapter 11A, Section 1115A, or Chapter 11B, Sections...
-
1007.2, Item 6
6. Platform lifts complying with Section 1007.5 and Chapter 11A, Section 1124A, or Chapter 11B, Sections 11B-206.7, 11B-207.2 and 11B-410 as applicable.
-
1007.2, Item 9
9. Areas of refuge complying with Section 1007.6.
-
1007.2, Item 7
7. Horizontal exits complying with Section 1025.
-
1007.2, Item 2
2. Interior exit stairways complying with Sections 1007.3 and 1022, and Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable.
-
1009.2, Item 6
6. Platform lifts complying with Section 1009.5 and Chapter 11A, Section 1124A, or Chapter 11B, Sections 11B-206.7, 11B-207.2 and 11B-410 as applicable.
-
1009.2, Item 7
7. Horizontal exits complying with Section 1026.
-
1009.2, Item 4
4. Exterior exit stairways complying with Sections 1009.3 and 1027 and Chapter 11A, Section 1115A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable and serving levels...
-
1009.2, Item 9
9. Areas of refuge complying with Section 1009.6.
-
1009.2, Item 2
2. Interior exit stairways complying with Sections 1009.3 and 1023, and Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable.
-
1010.1.9.7 Delayed egress locks
An attempt to egress shall initiate an irreversible process that shall allow such egress in not more than 15 seconds when a physical effort to exit is applied to the egress side door hardware...
-
4.1.3(7)(d)
(d) Each door required by 4.3.10, Egress, shall comply with 4.13....
- SDC Sure Exit® PSB560 REX Pressure Sense Exit Bar
-
1011.5.2 Riser height and tread depth
[DSA-AC] For applications listed in Section 1.9.1 regulated by the Division of the State Architect-Access Compliance, see Chapter 11B, Section 11B-202. ......
-
1010.1.9.8.1 Delayed egress locking system
An attempt to egress shall initiate an irreversible process that shall allow such egress in not more than 15 seconds when a physical effort to exit is applied to the egress side door hardware...
-
1018.3 Aisles in Groups B and M
Exception: Nonpublic aisles serving less than 50 people and not required to be accessible by Chapter 11B, (see Section 11B-403) need not exceed 28 inches (711 mm) in width....
-
1018.5 Aisles in other than assembly spaces and Groups B and M
Exception: Nonpublic aisles serving less than 50 people and not required to be accessible by Chapter 11B (see Section 11B-403) need not exceed 28 inches (711 mm) in width....
-
1010.1.7 Door arrangement
Doors within individual dwelling units in Groups R-2 and R-3 other than adaptable or accessible dwelling units....
-
1015.3 Height
In Group F occupancies where exit access stairways serve fewer than three stories and such stairways are not open to the public, and where the top of the guard also serves as a handrail,...
-
1009.4.2 Area of refuge
The elevator shall be accessed from an area of refuge complying with Section 1009.6. Exceptions: Areas of refuge are not required at the elevator in open parking garages....