A4.1.3(9) Supervised automatic sprinkler systems have built in signals for monitoring features of the system such as the opening and closing of water control valves, the power...
Search Results "Accessible Means of Egress"
-
A4.1.3(9)
-
1007.2.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
ACCESSIBLE MEANS OF EGRESS
ACCESSIBLE MEANS OF EGRESS. A continuous and unobstructed way of egress travel from any accessible point in a building or facility to a public way....
-
1002.1 Definitions
The following terms are defined in Chapter 2: ACCESSIBLE MEANS OF EGRESS. AREA OF REFUGE. EXIT. GUARD ([DSA-AC, HCD 1 & HCD 2] or GUARDRAIL). HANDRAIL....
-
SECTION 1007 ACCESSIBLE MEANS OF EGRESS
SECTION 1007 ACCESSIBLE MEANS OF EGRESS...
-
1007.1 Accessible means of egress required
1007.1 Accessible means of egress required. Accessible means of egress shall comply with this section....
-
1007.2 Continuity and components
Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components:...
-
1007.2, Item 1
Accessible routes complying with Chapter 11A, Section 1110A.1 and 1120A, or Chapter 11B, Sections 11B-206 and 11B-402, as applicable....
-
1007.2, Item 2
2. Interior exit stairways complying with Sections 1007.3 and 1022, and Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable.
-
1007.2, Item 3
Interior exit access stairways complying with Sections 1007.3 and 1009.3, Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
1007.2, Item 4
4. Exterior exit stairways complying with Sections 1007.3 and 1026 and serving levels other than the level of exit discharge, and Chapter 11A, Section 1115A, or Chapter 11B, Sections...
-
1007.2, Item 5
5. Elevators complying with Section 1007.4, and Chapter 11A, Section 1124A, or Chapter 11B, Sections 11B-206.6 and 11B-407, as applicable.
-
1007.2, Item 6
6. Platform lifts complying with Section 1007.5 and Chapter 11A, Section 1124A, or Chapter 11B, Sections 11B-206.7, 11B-207.2 and 11B-410 as applicable.
-
1007.2, Item 7
7. Horizontal exits complying with Section 1025.
-
1007.2, Item 8
8. Ramps complying with Section 1010, and Chapter 11A, Sections 1114A and 1122A, or Chapter 11B, 11B-405, as applicable.
-
1007.2, Item 9
9. Areas of refuge complying with Section 1007.6.
-
1007.2, Item 10
10. Exterior area for assisted rescue complying with Section 1007.7.
-
1007.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
1007.3 Stairways
In order to be considered part of an accessible means of egress, a stairway between stories shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate...
-
1007.4 Elevators
In order to be considered part of an accessible means of egress, an elevator shall comply with the emergency operation and signaling device requirements of California Code of Regulations...
-
1007.5 Platform lifts
Platform (wheelchair) lifts shall not serve as part of an accessible means of egress, except where allowed as part of a required accessible route in Chapter 11A, Sections 1121A and 1124A...
-
1007.5.1 Openness
Platform lifts on an accessible means of egress shall not be installed in a fully enclosed hoistway....
-
1007.6 Areas of refuge
Every required area of refuge shall be accessible from the space it serves by an accessible means of egress....
-
1007.6.1 Size
Such wheelchair spaces shall not reduce the required means of egress width....