participants (e.g. the 5th percentile or approximately 95% of the study sample) could transfer independently to a platform at a height that was within one inch of the mean wheelchair or scooter seat...
Search Results "Seat Designation"
Commonly Searched Documents
-
Key Study findings:
-
Re: Rockwood Manufacturing Company BFM687 BFM Series Men's ADA Toilet Room Molded Plastic Sign
THIS SIGN DOES NOT APPEAR TO MEET CURRENT STANDARDS (BOLD FONT FAILS 703.2.6) THE LINK TO THE CUT SHEET IS BROKEN (SIGN MAY NOT BE AVAILABLE)
-
Re: Rockwood Manufacturing Company BFM688 BFM Series Women's ADA Toilet Room Molded Plastic Sign
THIS SIGN DOES NOT APPEAR TO BE COMPLIANT FONT (BOLD FAILS 703.2.6) LINK ON PAGE TO CUTSHEET IS BROKEN - SIGN MAY NOT BE AVAILABLE
-
226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with 902....
-
Adjustable Height Range Considered
See Analysis of Seat Heights for Wheeled Mobility Devices at: http://udeworld.com/analysis-of-seat-height-for-wheeled mobility-devices....
-
Supports (M301.3, M302.3, and M305.2)
technical criteria for transfer and positioning supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated...
- Evan Terry Associates
-
How to Measure Transfer Surface Height
To solve this problem, manufacturers have designed adjustable height examination tables to work with a variety of WMD’s....
-
Fair Housing Act Design Manual
The manual was first published in August, 1996, and this update is intended to provide clear and helpful guidance about ways to design and construct housing which complies with the Fair...
- Figure 607.2 Clearance for Bathtubs – Drawing from the U.S. Access Board
- Figure 608.3.3 Grab Bars for Alternate Roll-In Type Showers – Drawing from the U.S. Access Board
-
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
M302.4 Lift Compatibility
EXCEPTION: Where diagnostic equipment meets the requirements of M303 and provides a folding seat, the equipment shall not be required to comply with M302.4....
-
11B-226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with Section 11B...
-
11B-226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with Section 11B...
-
11B-226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with Section 11B...
-
M303.2.4.1 Breast Platforms
Wheelchair spaces beneath breast platforms shall comply with M303.2.4.1.
-
M303.2.4.1.1 Depth
Wheelchair spaces shall include knee and toe clearance 25 inches (635 mm) deep minimum and 28 inches (710 mm) deep maximum.
-
M303.2.4.1.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum from the toe end of the wheelchair...
-
1. Transfer Surface
[See subsections ...]
-
5.8.2 Knee and Toe Clearance Under Breast Platform
5.8.2 Knee and Toe Clearance Under Breast Platform. The overall knee and toe space should be increased to a minimum of 28 inches deep, from the initially proposed 25 inch absolute...
-
F221.2.1.2 Luxury Boxes, Club Boxes, and Suites in Arenas, Stadiums, and Grandstands
In each luxury box, club box, and suite within arenas, stadiums, and grandstands, wheelchair spaces complying with 802.1 shall be provided in accordance with Table...
-
5.8.2.5 Toe Height
5.8.2.5 Toe Height. The toe height should be 18 inches minimum, measured above the ground when the top of the breast platform is 34 inches above the ground.
-
5.8.2.7 Base Support Allowance
5.8.2.7 Base Support Allowance. Base support is permitted to obstruct the clear floor space if it fits within the allowed base support volume. Base supports can be a maximum of 1½...