A segment of curb at least 24” long beyond flares must be provided on both sides of curb ramps with side flares within marked crossings....
Search Results "Push Side"
Commonly Searched Documents
-
Diagonal Curb Ramps [§406.6]
-
11B-608.3.2 Standard roll-in type shower compartments
Grab bars shall be provided on the back wall and the side wall opposite the seat. Grab bars shall not be provided above the seat....
-
1009.7.2 Separation
The fire-resistance-rated exterior wall construction shall extend horizontally 10 feet (3048 mm) beyond the landing on either side of the landing or equivalent fire-resistance-rated construction...
-
407.4.1 Car Dimensions
Table 407.4.1 Elevator Car Dimensions Minimum Dimensions Door Location Door Clear Width Inside Car, Side to Side...
-
11B-604 Water closets and toilet compartments
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
Water Hydrants and Water Spouts [1011.2, 1011.3, and 1011.6]
At water hydrants, a minimum of 72 by 48 inches of clear ground space must be provided with the long side of the space adjoining or overlapping an ORAR or trail as applicable, or another...
-
Clear Floor Space [4.16.2]
Space at least 60 inches wide is necessary for side transfers and when provided a 56 inch depth is permitted for either a forward or side approach because of the maneuvering space available...
-
Temporary Solutions for Election Day: Accessible Entrance to Polling Place
Problem Three: Entrance door threshold has an abrupt change in level of more than 1/4 inch and no beveled sides....
-
5. Edge Protection
of the platform, and for double ramped entry platforms, the Committee recommended a minimum two-inch high edge protection on both sides of the platform....
-
809.2.5 Bedrooms in Emergency Transportable Housing Units
The clear floor space must be positioned for a parallel approach to the side of the bed and must be on an accessible route....
-
11B-610.3 Shower compartment seats
A seat in a standard roll-in shower compartment shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back wall to a point within...
-
1. Standing Supports
preferred side to hold onto the standing support....
-
M302.2.3 Size
The size of transfer surfaces shall be measured from center points of their opposing sides....
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
4.16.5* Flush Controls
Controls for flush valves shall be mounted on the wide side of toilet areas no more than 44 in (1120 mm) above the floor....
-
4.16.5* FLUSH CONTROLS
Controls for flush valves shall be mounted on the wide side of toilet areas no more than 44 in (1120 mm) above the floor....
-
6.3(2)
(2) Each one-bed room shall have a minimum clear floor space of 36 in (915 mm) along each side of the bed, and 42 in (1065 mm) between the foot of the bed and the wall....
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
F105.2.2 ASME
The communication system must be push button activated. The activation button must be permanently identified with the word "HELP."...
- Pepsi with Brigid presents: The Penelope Impact - The impact of one child on a community
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
Fire rings with double walls or insulation on the sides are recommended to prevent burns....
-
R305.2.7 Boarding and Alighting Areas
At boarding and alighting areas at sidewalk or street level transit stops for rail vehicles, detectable warning surfaces shall be placed at the side of the boarding and alighting area facing...
-
4. Faucet Controls
Are the faucet controls and shower wand positioned on the wall along the side of the shower seat so they are operable from the folding shower seat or from the shower wheelchair?...
-
D. Toilet Centerline
Is each accessible toilet centered 18" from the adjacent side wall, which is the distance that will permit a person with a mobility impairment to use the grab bars?...