Clear floor or ground space shall be positioned adjacent to the dishwasher door....
Search Results "Patient in Standing Position"
-
804.6.3 Dishwasher
-
§1630.2(o)(1)(ii)
(ii) Modifications or adjustments to the work environment, or to the manner or circumstances under which the position held or desired is customarily performed, that enable an individual...
-
§1630.2(n)(1) In general
The term essential functions means the fundamental job duties of the employment position the individual with a disability holds or desires....
-
§ 36.303(d)(2)
(2) A public accommodation that offers a customer, client, patient, or participant the opportunity to make outgoing telephone calls using the public accommodation's equipment on more than...
-
Refrigerator/Freezer: ADA Standard Section 804.6.6
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
11B-804.6.6 Refrigerator/freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
11B-804.6.6 Refrigerator/freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
404.2.8.2 Spring Hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
4.15.5(2)
(2) Free-standing or built-in units not having a clear space under them shall have a clear floor space at least 30 in by 48 in (760 mm by 1220 mm) that allows a person in a wheelchair to...
-
4.15.5(2)
(2) Free standing or built-in units not having a clear space under them shall have a clear floor space at least 30 in by 48 in (760 mm by 1220 mm) that allows a person in a wheelchair to...
-
11B-602.10 Bottle filling stations
Exception: Where bottle filling stations are provided at a drinking fountain for standing persons, the bottle filling station is not required to comply with this section provided a bottle...
-
Section 1630.2(m) Qualified Individual
This is sometimes referred to in the Rehabilitation Act caselaw as determining whether the individual is “otherwise qualified” for the position....
-
F206.2.8.1 Load and Unload Areas
Where load and unload areas have more than one loading or unloading position, at least one loading and unloading position shall be on an accessible route....
-
206.2.9.1 Load and Unload Areas
Where load and unload areas have more than one loading or unloading position, at least one loading and unloading position shall be on an accessible route....
-
Protruding Objects
Protruding Objects Baby changing tables cannot violate the protruding object requirements of TAS 204 and 307 in either an open or closed position since either position is a potential...
-
1132A.3, Item 2
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
11B-206.2.9.1 Load and unload areas
Where load and unload areas have more than one loading or unloading position, at least one loading and unloading position shall be on an accessible route....
-
1132A.3, Item 2
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
11B-206.2.9.1 Load and unload areas
Where load and unload areas have more than one loading or unloading position, at least one loading and unloading position shall be on an accessible route....
-
11B-206.2.9.1 Load and unload areas
Where load and unload areas have more than one loading or unloading position, at least one loading and unloading position shall be on an accessible route....
-
Jeff's Story - A Video about Living with Spina Bifida
Requires the Registered User plan or above. Login!
