6. The width of any component in the means of egress system shall not be less than the minimum width required by Section 1005.
Search Results "Door Maneuvering Clearance"
Commonly Searched Documents
-
1132A.3, Item 6
- SOSS Door Hardware UltraLatch Demonstration Video
-
Measuring Opening Force
Measuring Opening Force The maximum force pertains to the continuous application of force necessary to fully open a door, not the initial force needed to overcome the inertia of the door...
-
Spacing: ADA Standard Section 609.3
Section 609.3 covers the current ADA Standards for the grab bar spacing between the wall, objects above, below and at the ends of the grab bar.
-
Sleeping Areas: ADA Standard Section 806.2.3
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed. The clear floor space shall be positioned for parallel approach to the side of...
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed. The clear space shall be positioned for parallel approach...
-
Toilet Rooms South (Briefing Theater)
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). kk....
-
Lavatory & Accessory Layouts
The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper towel and drop it into the receptacle before exiting....
-
§ 38.95(a)(1) General
., lift, ramp or bridge plate) complying with either paragraph (b) or (c) of this section; sufficient clearances to permit a wheelchair or mobility aid user to reach a seating location;...
-
1132A.4, Item 4
Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
- McGuire Manufacturing Co., Inc. PW1151AWC: 1 1/2" Offset Sink 151A Stainless Steel Strainer
- McGuire Manufacturing Co., Inc. Heavy Finish Offset Lavatory Strainer
- McGuire Manufacturing Co., Inc. 1151WC: Offset Strainer with 151 Basket Strainer
- IPS Corporation Truebro® Basin Guard® Undersink Protective Enclosures
- McGuire Manufacturing Co., Inc. PW1149WC: 1 1/2" Offset Sink 149 Flat Strainer
- McGuire Manufacturing Co., Inc. 155WC: Offset Lavatory Strainer
- IPS Corporation Truebro® Lav Shield® Protective Lavatory Enclosure
- McGuire Manufacturing Co., Inc. PW1000WC: 1 1/2" Offset Sink
- McGuire Manufacturing Co., Inc. ProDrainWC: Lavatory Strainer Less Overflow
- Zurn Industries Rigid Lavatory Enclosure - Vandal Gard
- McGuire Manufacturing Co., Inc. 1152WC: Offset with 152 Wide Top Strainer
- McGuire Manufacturing Co., Inc. 1000WC: Offset Strainer - Offset Only
-
§ 38.153(c)(1)
(1) Doors shall have a minimum clear width when open of 30 inches (760 mm), measured from the lowest step to a height of at least 48 inches (1220 mm), from which point they may taper to...
-
14.4 Q. If a covered multifamily dwelling has a below grade common use parking garage, is there a requirement for a vertical clearance to allow vans to park?
In response to comments from the public that the Guidelines for parking specify minimum vertical clearance for garage parking, the Department responded: No national accessibility standards...