In residential dwelling units required to provide mobility features complying with 809.2 through 809.4, all doors and doorways providing user passage shall comply with 404....
Search Results "Door Maneuvering Clearance"
-
206.5.4 Residential Dwelling Units
-
5.8.2.1 Height of Breast Platform At Time of Measurement
All knee and toe clearances should be measured when the top of the breast platform is set at 34 inches above the floor....
-
5.8.2.7 Base Support Allowance Recommendation
To determine the necessary clearance for the footrests, the Committee used the footrest height data and subtracted the thickness of the footrests (~0.5 inch)....
-
11B-206.5.4 Residential dwelling units
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
-
11B-206.5.4 Residential dwelling units
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
-
11B-206.5.4 Residential dwelling units
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
- Behavioral Safety Products #TC230 Suicide Resistant Standard Trap Cover
-
D2. Clear Passage
Does at least one door or one side of a double leaf door at the accessible entrance provide at least 32 inches clear passage width when the door is open 90 degrees?...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group...
-
D6. Vestibule Clear Floor Space
[ADA Stds 4.13.7] Yes _____ No _____ If No, leave the inner door open or remove inner door, add power operators to both doors so they open at the same time or, modify the vestibule...
-
11B-604.8.1.1 Size
Wheelchair accessible compartments shall additionally provide maneuvering space complying with Section 11B-604.8.1.1.1, 11B-604.8.1.1.2, or 11B-604.8.1.1.3, as applicable....
-
11B-604.3.2 Overlap
routes, clear floor space and clearances required at other fixtures, and the turning space....
-
11B-604.3.2 Overlap
routes, clear floor space and clearances required at other fixtures, and the turning space....
-
§ 38.93(a)(1)
(1) At least one door on each side of the car from which passengers board opening onto station platforms and at least one adjacent doorway into the passenger coach compartment, if provided...
-
M302.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group...
-
M302.4.2 Clearance Around Base
The base of the diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination...
-
11B-503.5 Vertical clearance
spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide a vertical clearance...
-
11B-503.5 Vertical clearance
Advisory 11B-503.5 Vertical clearance. ...
- DORMA ED700 Low-Energy Swing Door Operator
-
Circular Cross Section and Clearance (§505.5, §505.7)
Circular Cross Section and Clearance (§505.5, §505.7)...
-
4(4)
(4) Except as noted in paragraphs (5) and (6) below, thresholds at exterior doors, including sliding door tracks, are no higher than 3/4 inch....
-
B4
For van-accessible spaces (particularly in a garage or parking structure), is there vertical clearance of at least 98 inches (8 feet - 2 inches) for the vehicle route to the parking space...