This section requires at least 20 percent, but not less than one, of each type of outdoor constructed feature provided at each location on trails, other than within facilities provided on...
Search Results "Outdoor Rinsing Shower"
Commonly Searched Documents
-
F247.5 Outdoor Constructed Features
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
36 CFR Part 1191 ABA Accessibility Guidelines, Outdoor Developed Areas - Preamble
Billing Code 8150‒01-P ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE BOARD 36 CFR Part 1191 RIN 3014-AA22 Architectural Barriers Act Accessibility Guidelines; Outdoor...
-
608.3.1 Transfer Type Shower Compartments
Figure 608.3.1 Grab Bars for Transfer Type Showers...
-
1011 Outdoor Constructed Features
[See subsections ...]
-
1011 Outdoor Constructed Features
[See subsections ...]
-
1011 Outdoor Constructed Features
[See subsections ...]
-
F244.2.3.1 Outdoor Constructed Features
Where provided, at least one of each type of outdoor constructed features shall comply with 1011....
-
Getting From Here to There—Outdoor Recreation Access Routes
Figure 36 shows an outdoor recreation access route connecting a parking lot and scenic overlook....
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
-
4.20.6 SHOWER UNIT
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used as a fixed shower head or as a hand-held shower shall be provided....
-
4.20.6 Shower Unit
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used both as a fixed shower head and as a hand-held shower shall be provided....
-
F247.5 Outdoor Constructed Features
Where outdoor constructed features are provided on trails, other than within facilities specified in F247.4, at least 20 percent, but not less than one, of each type of outdoor constructed...
-
Alternative Designs. Bathroom as Shower Room
Bathroom as Shower Room....
-
A4.21.1 GENERAL
Shower stalls that are 36 in by 36 in (915 mm by 915 mm) wide provide additional safety to people who have difficulty maintaining balance because all grab bars and walls are within easy...
-
608 Shower Compartments
Section 608 addresses transfer showers and roll-in showers and provides specifications for size and clearances, grab bars, seats, operable parts, shower spray units, thresholds, and enclosures...
-
11B-246 OUTDOOR DEVELOPED AREAS
[See subsections ...]
-
11B-246 Outdoor developed areas.
[See subsections ...]
-
11B-246 Outdoor developed areas
[See subsections ...]
- Able Outdoors
-
Showers
Several commenters requested that the final Guidelines provide dimensions on the appropriate width and height of showers and shower doors....
-
11B-608.6 Shower spray unit and water
SECTION TITLE NOTES 11B-608.6 Shower spray unit and water....
-
11B-608.9 Shower floor or ground surface
11B-608.9 Shower floor or ground surface. Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....