Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
Search Results "Compartment Door"
-
11B-404.2.8.1 Door closers and gate closers
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
C. Toilet Rooms:
PSE shall provide at least seventeen (17) ambulatory accessible and/or 60-inch wide accessible toilet compartments with an outward swinging, self-closing door disbursed as set forth in the...
-
11B-409.3 Elevator doors
Hoistway doors, car doors, and car gates shall comply with Sections 11B-409.3 and 11B-404....
-
11B-409.3 Elevator doors
Hoistway doors, car doors, and car gates shall comply with Sections 11B-409.3 and 11B-404....
-
Location: ADA Standard Section 604.2
Section 604.2 covers the current ADA Standards for the mounting location of water closets.
-
604.9.7 Toilet Compartments
604.9.7 Toilet Compartments. Toilet compartments shall comply with 604.8....
-
4.22.4 Water Closets
complying with 4.17; where 6 or more stalls are provided, in addition to the stall complying with 4.17.3, at least one stall 36 in (915 mm) wide with an outward swinging, self-closing door...
-
Doors and Gates: ADA Standard Section 410.6
Section 410.6 covers the current ADA Standards for the doors and gates of platform lifts.
-
604.9.7 Toilet Compartments
Toilet compartments shall comply with 604.8....
-
604.9.7 Toilet Compartments
Toilet compartments shall comply with 604.8....
-
AUTOMATIC DOOR
[DSA-AC] A door equipped with a power operated mechanism and controls that open and close the door automatically upon receipt of a momentary actuating signal....
-
AUTOMATIC DOOR
[DSA-AC] A door equipped with a power operated mechanism and controls that open and close the door automatically upon receipt of a momentary actuating signal....
-
Doors, Doorways, and Gates: ADA Standard Section 206.5
Section 206.5 covers scoping requirements in the most current ADA Standards for accessible routes to doors, doorways, and gates.
-
G. Compartment Size
G. If the accessible toilet is in a stall, does the stall measure at least 60" wide and 56" deep if it is wall mounted or 59" deep if it is floor mounted to allow persons who use...
-
11B-604.9.7 Toilet Compartments
11B-604.9.7 Toilet Compartments. Toilet compartments shall comply with Section 11B-604.8....
-
Ambulatory Accessible Toilet Compartments
with six or more toilet compartments....
-
Location: ADA Standard Section 604.9.1
Section 604.9.1 covers the current ADA Standards for the mounting location of children's use water closets.
-
11B-604.9.1 Location
side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...
-
11B-604.9.1 Location
side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...
-
Restrooms Main Lobby
The restroom vestibule door does not have the required minimum of 18" maneuvering clearance on the latch side of the door. See Standards § 4.13.6. l....
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured perpendicular...
-
Doors in Series and Gates in Series: ADA Standard Section 404.2.6
Section 404.2.6 covers the current ADA Standards for doors in series and gates in series.