Operable parts shall be placed within one or more of the reach ranges specified in 308....
Search Results "Maximum Reach Depth"
-
309.3 Height
-
11B-411.4.6.1 Location
Controls shall be located within one of the reach ranges specified in Section 11B-308....
-
11B-411.4.6.1 Location
Controls shall be located within one of the reach ranges specified in Section 11B-308....
- Guldmann GL5 Mobile Lifter
-
Which transition type do users with disabilities prefer?
When a sidewalk slopes more than 2% in the direction of travel and a walk with a maximum 2% cross slope intersects it, which transition segment type provides the safest usability for the...
-
Character Spacing: ADA Standard Section 703.2.7
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....
-
11B-703.2.7 Character spacing
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
11B-703.2.7 Character spacing
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
11B-403.7 Continuous gradient
All walks with continuous gradients shall have resting areas, 60 inches (1524 mm) in length, at intervals of 400 feet (121,920 mm) maximum....
-
Clear Floor Space: ADA Standard Section 602.2
Section 602.2 covers the current ADA Standards for drinking fountain clear floor space.
-
11B-403.7 Continuous gradient
All walks with continuous gradients shall have resting areas, 60 inches (1524 mm) in length, at intervals of 400 feet (121,920 mm) maximum....
-
11B-705.1.2.2.2 Parallel curb ramps
Detectable warnings at parallel curb ramps shall be located so the edge nearest the curb is 6 inches (152 mm) minimum and 8 inches (203 mm) maximum from the demarcation line at the face...
-
11B-705.1.2.2.2 Parallel curb ramps
Detectable warnings at parallel curb ramps shall be located so the edge nearest the curb is 6 inches (152 mm) minimum and 8 inches (203 mm) maximum from the demarcation line at the face...
-
3. Flush valve
Flush valve is located in reach range and is operable without tight grasping, twisting, or pinching....
-
4.31.7 Telephone Books
Telephone books, if provided, shall be located in a position that complies with the reach ranges specified in 4.2.5 and 4.2.6....
-
4.31.7 TELEPHONE BOOKS
Telephone books, if provided, shall be located in a position that complies with the reach ranges specified in 4.2.5 and 4.2.6....
-
406.8--Modification to 406 of Appendix D to 36 CFR Part 1191
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum...
-
11B-805 Medical care and long-term care facilities
Exception 1 which states: "At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish floor or ground at a depth...
-
BitStarz No Deposit Bonus: Free Spins, Rules & Requirements
Maximum Withdrawal From the No Deposit Bonus BitStarz's current terms place a maximum on winnings generated from no-deposit bonuses and free spins....
-
surface mounted toilet paper dispensers
I feel this should be a future code modification to require at least semi-recessed styles with the maximum allowable projection limited to approximately the grab bar projection limits....
-
Size and Clearances [4.21.2]
Recommendations: Consider additional clear floor space beyond the control wall to facilitate the reach to controls....
-
When door vision lights are limited to 100 square inches by the fire code, is compliance with the specified maximum height of 43” to the bottom edge still required?
Yes. The Standards do not exempt such doors from the requirement for vision lights (§404.2.11). However, compliance is not required when the lowest part of the vision light is more...